2000 Mitsubishi MonteroFACTORY OEM SERVICE PROCEDURE

Rectifier Assembly

  1. Using ohmmeter, check for continuity between diodes and stator coil lead connection. See Fig 1 . Reverse leads. If continuity is present in both directions, diode is shorted. Replace rectifier assembly.
  2. To check entire diode assembly, use an ohmmeter to check for continuity between both ends of each diode. See Fig 1 . Switch ohmmeter leads. Continuity should be present in one direction only. If continuity is not as specified, diode is defective. Replace rectifier assembly.
Fig 1: Testing Rectifier Assembly
G90E08767Courtesy of MITSUBISHI MOTOR SALES OF AMERICA
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.