Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
1994 Mitsubishi Eclipse Base, AutomaticFACTORY OEM SERVICE PROCEDURE
Fuel Pressure Regulator Control Solenoid Valve (Turbo Models)
- Label and remove vacuum hoses from solenoid valve. Disconnect wiring harness. Connect vacuum pump to nipple where Black vacuum hose was connected. Leave pump connected throughout procedure.
- Apply vacuum and ensure valve leaks. Plug nipple where Blue-striped hose was connected. Apply vacuum and ensure vacuum holds. Remove plug from Blue-striped hose nipple. Apply battery voltage across valve terminals. Apply vacuum and ensure vacuum holds.
- Using an ohmmeter, check resistance across terminals of solenoid. Resistance should be 36-46 ohms at 68°F (20°C). If resistance is not within specification, replace solenoid valve.
- If resistance is within specification, disconnect solenoid harness connector. Turn ignition on. Using DVOM, measure voltage between harness connector terminal (Red wire) and vehicle ground.
- If battery voltage is present, go to step 6). If battery voltage is not present, inspect and repair circuit between MFI relay and solenoid. If circuit is okay, inspect MFI relay. See RELAYS under MOTORS, RELAYS & SOLENOIDS. MFI relay is located near ECM, behind radio, under console.
- Disconnect ECM connector. See ENGINE CONTROL MODULE (ECM) LOCATION table under COMPUTERIZED ENGINE CONTROLS. Connect jumper wire between ECM terminal No. 6 (No. 57 on Eclipse) and vehicle ground. See Figure . Using DVOM, measure continuity between solenoid harness connector terminal Blue/Red wire (White wire on Eclipse) and vehicle ground.
- If continuity does not exist, check and repair circuit between solenoid and ECM. If continuity exists and all preceding tests do not show any system or component malfunction and ECM is suspected, substitute ECM with known good component and retest.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.