Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
1987 Mitsubishi Starion ESI-RFACTORY OEM SERVICE PROCEDURE
Component Testing: Turbocharged
- On Mirage and Starion models, connect a 1/2" O.D. hose to secondary air cleaner intake hose. On Cordia and Tredia models, disconnect air supply hose at air cleaner.
- On all models, start engine and warm to 104-140°F (40-60°C). There should be suction at hose at idle. When engine temperature reaches 158°F (70°C) or more, there should be no suction. Accelerate engine to 4000 RPM and as engine is decelerating, there should be suction at air hose.
- If these conditions are met, secondary air supply system is good. Replace reed valve if exhaust gases blow out of air hose.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.
