1986 Merkur XR4Ti AutomaticFACTORY OEM SERVICE PROCEDURE

Relay To EEC Continuity

Using an ohmmeter, check for continuity between relay terminal No. 85 and EEC pin No. 22. If there is continuity, pump circuit is okay. If no continuity, repair open in circuit.