1986 Merkur XR4Ti AutomaticFACTORY OEM SERVICE PROCEDURE

Timing Check

NOTE: If engine will not start, go to CIRCUIT TEST A  . If engine starts but stalls while testing, go to DIAGNOSIS BY SYMPTOM  TEST.
  1. Turn ignition switch to "OFF" position, and then wait 10 seconds. Verify that SELF-TEST has been activated. Restart engine and check timing while in SELF-TEST mode. You are allowed 2 minutes to check timing from the time the last code is displayed.
  2. Correct SELF-TEST timing equals base ignition timing (10° BTDC on all engines) plus 17-23° BTDC. If timing is not 27-33° BTDC, go to CIRCUIT TEST MM. If timing is 27-33° BTDC, go to ENGINE RUNNING SELF-TEST  .
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.