2011 Mercury Milan Base, AutomaticFACTORY OEM SERVICE PROCEDURE

Starting System: Specifications

GENERAL SPECIFICATIONS

Item Specification
Normal engine cranking speed 200-250 rpm
Starting circuit maximum voltage drop (engine at normal operating temperature) 0.5 volt
Starter motor maximum load current draw 800 amps
Starter motor no-load current draw 60-80 amps
Starter motor normal load current draw 130-190 amps
TORQUE SPECIFICATIONS

Description Nm lb-ft lb-in
Ground wire nut - 2.5L 18 - 159
Ground wire nut - 3.0L 18 - 159
Starter motor bolt and stud bolt (2.5L) 25 18 -
Starter motor bolts (3.5L) 27 20 -
Starter motor solenoid battery cable nut 12 - 106
Starter motor solenoid wire nut 5 - 44
Starter motor stud bolts (3.0L) 27 20 -
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.

Rather have a pro handle this?

A certified mobile mechanic comes to your home or office. They bring the tools, you stay comfortable. No tow truck, no waiting room, no surprises.

Comes to youSame-day available12-month warranty
Get a Free Quote

No obligation. See pricing before you book.