2006 Mercury MontereyFACTORY OEM SERVICE PROCEDURE

Component Testing Procedure

WARNING: This page is about a different car, the 2006 Ford Freestar. However, it is still accessible from the selected car via links, so may be relevant.
POWER WINDOW SWITCH, LH SIDE FRONT COMPONENT TESTING

Circuit to test Connect self-powered test light or ohmmeter to terminals Move switch to these positions A good switch will indicate
One-Touch Down Switch  4 and 6 Auto Down Closed circuit
Neutral Open circuit
Left front window circuit  4 and 7 Up Closed circuit
4 and 6 Down Closed circuit
Right front window circuit  8 and 3 Up Closed circuit
8 and 2 Down Closed circuit
Circuit to test Connect self-powered test light or ohmmeter to terminals Move switch to these positions A good switch will indicate
Power and Ground Checks Before Any Other Tests  8 (C508a) and 6 (C508a)
2 (C508a) and 6 (C508a)
All switches, all positions Open circuit
6 (C508a) and 1, 3, 5, 7 (508a)
6 (C508a) and 1, 3, 5, 7 (508b)
All switches, at rest Closed circuit
Left front window circuit  8 (508a) and 7 (508a) Up Closed circuit
8 (508a) and 3 (508a) Down Closed circuit
Right front window circuit  2 (508a) and 1 (508a) Up Closed circuit
2 (508a) and 5 (508a) Down Closed circuit
Left rear window circuit  8 (508a) and 1 (508b) Up Closed circuit
8 (508a) and 4 (508b) Down Closed circuit
Right rear window circuit  8 (508a) and 6 (508b) Up Closed circuit
8 (508a) and 3 (508b) Down Closed circuit
One-Touch Down Switch  8 (508a) and 4 (508a) One-Touch Down Switch Closed circuit
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.