2000 Mercury Villager BaseFACTORY OEM SERVICE PROCEDURE

Test B: System Is Not Charging, Charge Warning Indicator Operates Properly

  1. Perform NO-LOAD TEST  under ON-VEHICLE TESTING. If generator output is lower than specified, go to next step. If generator output is as specified, check battery state of charge and perform battery load test according to load tester manufacturer's instructions.
  2. Turn ignition off. Inspect drive belt condition and tension. See ADJUSTMENTS  . Adjust, repair or replace belt as necessary and check system operation. If drive belt is okay, disconnect generator terminal B+ (Black wire on 1999 models, Black/White wire on 2000 models) connector. Measure voltage between generator B+ connector terminal and ground. If battery voltage is present, go to next step. If battery voltage is not present, repair circuit and check system operation. See WIRING DIAGRAMS  .
  3. Disconnect generator 2-pin connector. Measure voltage between generator connector Blue wire terminal and ground. If battery voltage is present, go to next step. If battery voltage is not present, repair circuit and check system operation. See WIRING DIAGRAMS  .
  4. Disconnect generator ground connector (smaller gauge Black wire). Measure resistance between generator connector Black wire and ground. If resistance is greater than 5 ohms, repair ground wire or ground connection, and check system operation. If resistance is 5 ohms or less, replace generator. See GENERATOR  under REMOVAL & INSTALLATION.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.