1999 Mercury Villager BaseFACTORY OEM SERVICE PROCEDURE

Test B: Pcm Relay

Enter this test only when directed here by other tests. To prevent replacement of good components, check for faults in following components:

  • Ignition switch.
  • Generator.
  • Battery cables, ground straps and voltage regulator.

This test is only intended to diagnose the following components and circuits:

  • Harness circuits; VPWR and ground.
  • PCM relay.

  1. Check VPWR To PCM

    Turn ignition off. Disconnect PCM. Connect jumper wire between PCM relay PCMR circuit and PCM terminal No. 4. See Fig 1. Turn ignition on. Measure voltage between ground and PCM terminals No. 66, 71 and 97. See Fig 2. If voltage is less than 10 volts, go to next step. If voltage is greater than 10 volts, go to step Β 7. If sent here from switch monitor test and voltage is greater than 10 volts, go to next step.
    Fig 1: PCM Connector Terminal Identification
    G99F02657Courtesy of FORD MOTOR CO.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.