1996 Mercury Tracer TrioFACTORY OEM SERVICE PROCEDURE

All Power Windows Inoperative

  1. Fuse Check  - Ensure ignition is off. Check POWER WINDOW (30-amp) fuse. If fuse is blown, go to next step. If fuse is okay,go to step 4).
  2. System Check  - Turn ignition off. Replace POWER WINDOW fuse. If fuse repeatedly blows, go to next step. If fuse does not blow, go to step 4).
  3. Circuit Check  - Turn ignition off. Locate and unplug 6-pin interior fuse junction panel connector. Access and unplug master power window switch connector. Measure resistance between Black/White wire at interior fuse junction panel connector and ground. If resistance is greater than 10 k/ohms, go to next step. If resistance is less than 10 k/ohms, Repair Black/White wire.
  4. Ground Check  - Turn ignition off. Unplug power window master switch connector. See Fig 1 and Fig 2 . Measure resistance between Black wire at power window master switch connector and ground. If resistance is less than 5 ohms, go to next step. If resistance is greater than 5 ohms, repair open in Black wire. Retest system.
  5. Power Window Master Switch Check  - Perform master switch test. See MASTER SWITCH  under COMPONENT TESTING. If master switch is good, repair Black/White wire between interior fuse junction panel and power window master switch. If master switch is faulty, replace switch and retest system.
Fig 1: Master Switch Terminal ID (3-Door - Escort & Tracer)
G96G01333Courtesy of FORD MOTOR CO.
Chapter Navigation
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.