1992 Mercury Capri Base, AutomaticFACTORY OEM SERVICE PROCEDURE

A7: Check Power Window Main Switch

Turn ignition on, with engine off. Locate power window main switch. Check voltages between Black wire and and other terminals. See WIRING DIAGRAMSΒ  . See Figure . If all voltages are not correct, replace power window main switch. If all voltages ARE correct, and driver's windows does not work, go to A11: Check Power Window Motor Circuit ContinuityΒ  . If all voltages ARE correct and passenger's window does not work, go to A8: Check Wire To Passenger SwitchΒ  .

Fig 1: Testing Power Window Main Switch Voltages
G00094660Courtesy of FORD MOTOR CO.