Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
Knock Control, Function - GF07.10-P-1015MNF
Engine 176.9 in model 463Â
as of model year 2016 up to model year 2019Â
Function requirements for knock control, general pointsÂ
- Circuit 87M (Engine management ON)
- Engine runs
The circuit relay 87M(F58kN) is switched on for circuit 15 ON.
Knock control, general pointsÂ
The knock control is integrated in the ME-SFI [ME] control unit (N3/10) and has the task is to ensure knock-free engine operation when different fuel grades are used and under all operating conditions. In the case of uncontrolled combustion (knocking), the ignition angle of the ignition coil for cylinders 1 + 2 to cylinders 7 + 8 (T4 to T4/3) for the relevant cylinder is adjusted in direction of "retard".
The ME-SFI [ME] control unit regulates the knock control dependent on the following signals:
- Knock sensor 1 (A16/1)
- Knock sensor 2 (A16/2)
- Knock sensor 3 (A16/3)
- Knock sensor 4 (A16/4)
- Left intake camshaft Hall sensor (B6/4) and right intake camshaft Hall sensor (B6/5), intake camshaft positions (ignition circuit detection)
- Left exhaust camshaft Hall sensor (B6/6) and right exhaust camshaft Hall sensor (B6/7), exhaust camshaft positions (ignition circuit detection)
- Coolant temperature sensor (B11/4), coolant temperature
- Left charge air temperature sensor (B17/14) and right charge air temperature sensor (B17/15), charge air temperature
- Pressure sensor downstream of left throttle valve (B28/22) and pressure sensor downstream of right throttle valve (B28/23), engine load
- Accelerator pedal sensor (B37), load request by driver
- Crankshaft Hall sensor (B70), engine speed and crankshaft position (ignition circuit detection)
- RON default setting (Research Octane Number) over Xentry Diagnostics
The requirements of the torque coordination function are also taken into account.
Function sequence for knock controlÂ
The knock control function includes the following subfunctions:
- Function sequence for ignition angle settingÂ
- Function sequence for RON correctionÂ
- Function sequence for knock control adaptationÂ
- Function sequence for knock identification errorÂ
Function sequence for ignition angle settingÂ
Knock control is enabled under the following operating conditions:
- Coolant temperature>30 °C
- Engine load > 34 %
According to its input signals, the ME-SFI [ME] control unit computes the cylinder-specific ignition angle correction.
If knocking is detected on one of the cylinders by the knock sensors, its ignition angle (depending on engine speed) is adjusted in direction of "retard" as from the next ignition by 3° of the crank angle (CKA). If knocking still occurs, the ignition angle is retarded by about another 3° of the crank angle and so on until the maximum shift value is reached (about a 15° CKA).
If there is no knocking combustion, after a few ignitions the retarding the ignition timing is reversed in operation steps of about 0.75 ° crank angle until the normal performance map value is reached or until knocking occurs again.
Function sequence for RON correctionÂ
The RON correction can be preset using Xentry Diagnostics by means of correction programming. The regulated RON stage remains until stopping of the engine.
Function sequence for knock control adaptationÂ
Adaptation of the knock control becomes active starting from a coolant temperature of about 70 °C. The ignition angle corrections required due to combustion knocking are stored continuously for the specific cylinder, along with the related operating condition of the engine (engine load and engine speed). When determining the individual ignition angles, the stored adaptation values are taken into account, so that the optimal ignition angle can be calculated immediately for each cylinder.
Function sequence for knock identification errorÂ
For safety reasons, if one of the knocking sensor signals fails, the ignition angles of all cylinders is retarded by up to 12° crank angle (according to engine speed and coolant temperature). Knock control and its adaptation are deactivated and a fault is stored in the fault memory.
| Â | Electrical function schematic for knock control | Â | PE07.10-P-2715-97ZGD |
| Â | Overview of system components for gasoline injection and ignition system with direct injection | Â | GF07.70-P-9998MNFÂ |
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.