2021 Mercedes Benz E350 BaseFACTORY OEM SERVICE PROCEDURE

Knock Control, Function - GF07.10-P-1015MRD

Engine 274.9 in model 213, 238 

up to model year 2021 

Function requirements, general 

  • Engine runs

IMPORTANT The ME-SFI [ME] control unit (N3/10) detects engine running via the evaluation of the crankshaft Hall sensor signals (B70). The ME-SFI [ME] control unit directly reads in the signals of the crankshaft Hall sensor.

Knock control, general points 

The function of the knock control is to ensure operation without uncontrolled engine combustions (knocking) for different fuel grades and all operating conditions. If the sensor system detects knocking combustion, the ME-SFI [ME] control unit adjusts the ignition of the affected cylinder in the "retarded" direction.

The ME-SFI [ME] control unit controls the knock control dependent on the signals of the following sensors:

  • Knock sensor 1 (A16/1)
  • Knock sensor 2 (A16/2)
  • Intake camshaft Hall sensor (B6/15)
  • Exhaust camshaft Hall sensor (B6/16)
  • Coolant temperature sensor (B11/4)
  • Pressure sensor downstream of throttle valve (B28/7)
  • Accelerator pedal sensor (B37)

    The powertrain control unit (N127) directly reads in the signals of the accelerator pedal sensor and transmits these via the drive CAN (CAN C1) to the ME-SFI [ME] control unit.

  • Crankshaft Hall sensor

The requirements of the torque coordination function are also taken into account.

IMPORTANT If a knock sensor fails, the ignition angles of all cylinders are adjusted by up to 12° in the "retarded" direction for safety reasons. The knock control is blocked and a fault is stored in the fault memory.

IMPORTANT The research octane number (RON) can be changed using the diagnostic tester. The ME-SFI [ME] control unit adapts the knock control accordingly.

The knock control detects a persistently high knocking tendency and accordingly counteracts this. For this purpose, the knock control evaluates the number of control interventions in certain engine load and RPM ranges. From a defined threshold, the presetting (RON stage) is changed.

Ignition angle setting 

Knock control is enabled under the following operating conditions:

  • Coolant temperature above 30°C
  • Engine load above 34 %

The ME-SFI [ME] control unit evaluates all incoming information and calculates the cylinder-specific ignition angle corrections.

If knocking combustion is detected at a cylinder, the ME-SFI [ME] control unit adjusts the ignition angle at this cylinder by approx. 3° in the "retarded" direction as of the next ignition. If further knocking combustion is then detected, the ME-SFI [ME] control unit adjusts the ignition angle by an additional 3° in the "retarded" direction. The ignition angle can be adjusted by a maximum of 15° in the "retarded" direction. When the combustion is then free of knocking, the ME-SFI [ME] control unit gradually reduces the retarding (steps of approx. 0.75°) until the normal performance map value has been reached or knocking starts again.

The ME-SFI [ME] control unit actuates the following components for the ignition angle setting:

  • Cylinder 1 ignition coil (T1/1)
  • Cylinder 2 ignition coil (T1/2)
  • Cylinder 3 ignition coil (T1/3)
  • Cylinder 4 ignition coil (T1/4)

IMPORTANTAdaptation of knock control 

The adaptation of the knock control is active from a coolant temperature of 75°C The ignition angle corrections required due to combustion knocking are stored continuously in a cylinder-specific way, together with the respective operating state of the engine (engine load and engine RPM). If knocking combustion starts again, the stored adaptation values are taken into account so that the optimal ignition angle can be set immediately for each cylinder.

  Electrical function schematic for knock control   PE07.10-P-2715-97DBD
  Overview of system components for gasoline Engine 274.9 in model 213 (except injection and ignition system with direct 213.050/053/153), 238 injection up to model year 2021 GF07.70-P-9998MRD
    Engine 274.9 in model 213.050/053/153 up to model year 2021 GF07.70-P-9998MRP
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.