2021 Mercedes Benz CLS450 BaseFACTORY OEM SERVICE PROCEDURE

Injection Regulation, Function - GF07.10-P-1004MRT

Engine 256.9 in model 213, 238, 257, 290 

up to model year 2021 

Engine 256.9 in model 222 

Function requirements, general 

  • Engine runs

IMPORTANT The ME-SFI [ME] control unit (N3/10) detects the engine running via the evaluation of the crankshaft Hall sensor signals (B70). The ME-SFI [ME] control unit directly reads in the signals of the crankshaft Hall sensor.

Injection control 

The injection control distributes the required fuel quantity to each cylinder in a demand-based way. The fuel quantity results from the injection duration and the injection pressure when doing this.

The ME-SFI [ME] control unit calculates the injection duration and injection pressure based on the following signals:

  • Fuel pressure and temperature

    Fuel pressure and temperature sensor (B4/25)

  • Intake camshaft position

    Intake camshaft Hall sensor (B6/15)

  • Exhaust camshaft position

    Exhaust camshaft Hall sensor (B6/16)

  • Coolant temperature

    Coolant temperature sensor (B11/4)

  • Engine load

    Pressure and temperature sensor downstream of turbocharger (B28/17)

  • Engine loading request

    The powertrain control unit (N127) reads in the accelerator pedal sensor (B37) signals directly, and transmits the accelerator pedal position via the drive CAN (CAN C1) to the ME-SFI [ME] control unit.

  • Engine speed

    Crankshaft Hall sensor

  • Nitrogen oxide and oxygen concentration in exhaust gas Oxygen sensor downstream of catalytic converter (G3/1)
    • Oxygen sensor sensor element downstream of catalytic converter (G3/1b1)

    Oxygen sensor upstream of catalytic converter (G3/2)

    • Oxygen sensor sensor element upstream of catalytic converter (G3/2b1)
  • Atmospheric pressure for altitude adaptation

    The atmospheric pressure sensor is integrated in the ME-SFI [ME] control unit.

The requirements of the torque coordination function are also taken into account.

The ME-SFI [ME] control unit actuates the following components for the injection control:

  • Cylinder 1 fuel injector (Y76/1)
  • Cylinder 2 fuel injector (Y76/2)
  • Cylinder 3 fuel injector (Y76/3)
  • Cylinder 4 fuel injector (Y76/4)
  • Cylinder 5 fuel injector (Y76/5)
  • Cylinder 6 fuel injector (Y76/6)

The ME-SFI [ME] control unit makes a distinction between the following operating conditions when doing this:

  • Engine start 
  • Idle speed 
  • Partial load, full load 
  • Accelerate 

IMPORTANT The engine start and idle operating conditions are described in separate documents.

Partial load, full load 

The ME-SFI [ME] control unit calculates the actuation time of the fuel injectors depending on lambda control, the fuel pressure in the rail, and the requested engine torque.

IMPORTANT At the accelerator pedal sensor, approx. 10% to 90% slewing range are defined as partial load and more than approx. 90% slewing range as wide open throttle.

Multiple injection 

With multiple injection, the fuel injectors are actuated multiple times in succession. The injection quantity is distributed to multiple single fuel injections.

Multiple injections can occur with the following actions:

  • Start
  • Heat up CAT
  • Combustion stabilization at high loads and speeds of more than 2000 rpm
  • Keep the CAT in idle for long idling phases for a run engine

Accelerate 

When there is rapid change in the accelerator pedal position, the throttle valve also opens and closes rapidly. This causes the mixture to briefly become leaner or too rich. To prevent this, the ME-SFI [ME] control unit adjusts the fuel/air mixture by increasing or shortening the actuation time of the fuel injectors in a characteristics map-dependent manner. This prevents jerking of the engine.

  Electrical function schematic for injection control Engine 256.9 in model 213, 238 up to model year 2021 PE07.10-P-2704-97DBA
    Engine 256.9 in model 222 PE07.10-P-2704-97SEM
    Engine 256.9 in model 257 up to model year 2021 PE07.10-P-2704-97XBB
  Overview of system components for gasoline injection and ignition system with direct injection   GF07.70-P-9998MRT 
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.