2017 Mercedes Benz GLS450FACTORY OEM SERVICE PROCEDURE

Ignition Off, Function - GF07.10-P-1002MNG

ENGINE 276.8 in MODEL 292 

ENGINE 276.8/9 in MODEL 166 (except 166.063) 

as of model year 2016 

Function requirements for ignition OFF, general points 

  • Circuit 87M (engine management ON)
  • Circuit 15 (ignition ON)

Ignition OFF, general points 

With the ignition OFF, first the engine and then the engine management are switched off in the ME-SFI [ME] control unit (N3/10).

Function sequence for ignition OFF 

With the ignition OFF, the circuit 15 relay (F58kR) is switched off by the electronic ignition lock control unit (N73) via interior CAN (CAN B) and by the SAM control unit (N10). The signal "circuit 15 OFF" is sent redundantly via the chassis CAN1 (CAN E1) to the ME-SFI [ME] control unit.

If the ME-SFI [ME] control unit receives the "circuit 15 OFF" signal via the circuit 15 relay, the engine is switched off by shutting off the fuel pump (M3), the fuel injectors (Y76) and the ignition coils (T1) are switched off and computer run-on is started.

IMPORTANT Information for partial function "no-load current shutoff" is documented in the function description "Engine OFF energy management function".

Ground connection "circuit 31" takes place by the on-board electrical system battery (G1) over the on-board electrical system battery ground point at the front right (W10) and over a number of ground lines to the ground point on the front right for the lamp unit (W2).

When the ignition is OFF, the ME-SFI [ME] control unit is supplied with power from the on-board electrical system battery via "circuit 30 fused".

  Electrical function schematic for ignition OFF   PE07.10-P-2702-97NBG
  Overview of system components for gasoline injection and ignition system with direct injection ENGINE 276.8 in MODEL 166 (except 166.063)
as of model year 2016
ENGINE 276.8 in MODEL 292
GF07.70-P-9998MMX
    ENGINE 276.9 in MODEL 166
as of model year 2016
GF07.70-P-9998MNG
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.