Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
2016 Mercedes Benz C300 BaseFACTORY OEM SERVICE PROCEDURE
Drivetrain Control DTCS (CEPC Module)
DRIVETRAIN CONTROL DTCS (CEPC MODULE)
| MB DTC | Description |
| B10BC00 | PTC heater booster "High voltage" has a malfunction. |
| B10BCD4 | PTC heater booster "High voltage" has a malfunction. |
| B11C113 | The additional battery has a malfunction. There is an open circuit. |
| B11C116 | The additional battery has a malfunction. The limit value for electrical voltage has not been attained. |
| B11C118 | The additional battery has a malfunction. The limit value for current has not been attained. |
| B11C11B | The additional battery has a malfunction. The limit value for resistance has been exceeded. |
| B11E100 | Temperature sensor 'Refrigerant' has a malfunction. |
| B11E111 | Temperature sensor 'Refrigerant' has a malfunction. There is a short circuit to ground. |
| B11E116 | Temperature sensor 'Refrigerant' has a malfunction. The limit value for electrical voltage has not been attained. |
| B11E117 | Temperature sensor 'Refrigerant' has a malfunction. The limit value for electrical voltage has been exceeded. |
| B210D00 | The power supply is too low. |
| B210E00 | The power supply is too high. |
| B218E00 | Actuation of the radiator shutters has a malfunction. |
| B218E87 | Actuation of the radiator shutters has a malfunction. The message is missing. |
| B219304 | There is an internal fault in the battery sensor. There is an internal fault. |
| B21DE11 | The relay 'Additional battery' has a malfunction. There is a short circuit to ground. |
| B21DE15 | The relay 'Additional battery' has a malfunction. There is a short circuit to positive or an open circuit. |
| B21DE71 | The relay 'Additional battery' has a malfunction. The actuator is blocked. |
| B21DF11 | The relay 'Decoupling of starter battery' has a malfunction. There is a short circuit to ground. |
| B21DF15 | The relay 'Decoupling of starter battery' has a malfunction. There is a short circuit to positive or an open circuit. |
| B21DF71 | The relay 'Decoupling of starter battery' has a malfunction. The actuator is blocked. |
| B3A0077 | There is currently no further information available on this fault code. |
| B3A0096 | There is currently no further information available on this fault code. |
| C210000 | The power supply at input 'Circuit 30' is too low. |
| C210100 | The power supply at input 'Circuit 30' is too high. |
| P000001 | The quantity control valve has an electrical fault or an open circuit. There is a general signal fault. |
| P000100 | The quantity control valve has an electrical fault or an open circuit. |
| P000101 | The quantity control valve has an electrical fault or an open circuit. There is a general electrical fault. |
| P000102 | The quantity control valve has an electrical fault or an open circuit. There is a general signal fault. |
| P000103 | The quantity control valve has an electrical fault or an open circuit. There is a frequency or pulse width modulation fault. |
| P000104 | The quantity control valve has an electrical fault or an open circuit. There is an internal fault. |
| P000105 | The quantity control valve has an electrical fault or an open circuit. There is a programming fault. |
| P000106 | The quantity control valve has an electrical fault or an open circuit. There is an algorithm fault. |
| P000107 | The quantity control valve has an electrical fault or an open circuit. There is a mechanical fault. |
| P000108 | The quantity control valve has an electrical fault or an open circuit. There is a signal fault or the message is faulty. |
| P000109 | The quantity control valve has an electrical fault or an open circuit. There is a component fault. |
| P00010A | The quantity control valve has an electrical fault or an open circuit. |
| P00010B | The quantity control valve has an electrical fault or an open circuit. |
| P00010C | The quantity control valve has an electrical fault or an open circuit. |
| P00010D | The quantity control valve has an electrical fault or an open circuit. |
| P00010E | The quantity control valve has an electrical fault or an open circuit. |
| P00010F | The quantity control valve has an electrical fault or an open circuit. |
| P000110 | The quantity control valve has an electrical fault or an open circuit. Reserved for ISO/SAE |
| P000111 | The quantity control valve has an electrical fault or an open circuit. There is a short circuit to ground. |
| P000112 | The quantity control valve has an electrical fault or an open circuit. There is a short circuit to positive. |
| P000113 | The quantity control valve has an electrical fault or an open circuit. There is an open circuit. |
| P000114 | The quantity control valve has an electrical fault or an open circuit. There is a short circuit to ground or an open circuit. |
| P000115 | The quantity control valve has an electrical fault or an open circuit. There is a short circuit to positive or an open circuit. |
| P000116 | The quantity control valve has an electrical fault or an open circuit. The limit value for electrical voltage has not been attained. |
| P000117 | The quantity control valve has an electrical fault or an open circuit. The limit value for electrical voltage has been exceeded. |
| P000118 | The quantity control valve has an electrical fault or an open circuit. The limit value for current has not been attained. |
| P000119 | The quantity control valve has an electrical fault or an open circuit. The limit value for current has been exceeded. |
| P00011A | The quantity control valve has an electrical fault or an open circuit. The limit value for resistance has not been attained. |
| P00011B | The quantity control valve has an electrical fault or an open circuit. The limit value for resistance has been exceeded. |
| P00011C | The quantity control valve has an electrical fault or an open circuit. The voltage value is outside the permissible range. |
| P00011D | The quantity control valve has an electrical fault or an open circuit. The current value is outside the permissible range. |
| P00011E | The quantity control valve has an electrical fault or an open circuit. The resistance value is outside the permissible range. |
| P00011F | The quantity control valve has an electrical fault or an open circuit. There is a sporadic fault. |
| P000120 | The quantity control valve has an electrical fault or an open circuit. Reserved for ISO/SAE |
| P000121 | The quantity control valve has an electrical fault or an open circuit. The signal amplitude is less than the minimum amplitude. |
| P000122 | The quantity control valve has an electrical fault or an open circuit. The signal amplitude is greater than the maximum amplitude. |
| P000123 | The quantity control valve has an electrical fault or an open circuit. No signal change: Voltage level is too low. |
| P000124 | The quantity control valve has an electrical fault or an open circuit. No signal change: Voltage level is too high. |
| P000125 | The quantity control valve has an electrical fault or an open circuit. There is a faulty signal waveform. |
| P000126 | The quantity control valve has an electrical fault or an open circuit. The signal change rate is below the permissible limit value. |
| P000127 | The quantity control valve has an electrical fault or an open circuit. The signal change rate is above the permissible limit value. |
| P000128 | The quantity control valve has an electrical fault or an open circuit. The signal offset is outside the permissible range. |
| P000129 | The quantity control valve has an electrical fault or an open circuit. There is an invalid signal. |
| P00012A | The quantity control valve has an electrical fault or an open circuit. There is no signal change. |
| P00012B | The quantity control valve has an electrical fault or an open circuit. The electrical lines have a short circuit to each other. |
| P00012C | The quantity control valve has an electrical fault or an open circuit. |
| P00012D | The quantity control valve has an electrical fault or an open circuit. |
| P00012E | The quantity control valve has an electrical fault or an open circuit. |
| P00012F | The quantity control valve has an electrical fault or an open circuit. There is an erratic signal. |
| P000130 | The quantity control valve has an electrical fault or an open circuit. Reserved for ISO/SAE |
| P000131 | The quantity control valve has an electrical fault or an open circuit. The signal is not present. |
| P000132 | The quantity control valve has an electrical fault or an open circuit. The off-time of the signal frequency is too short. |
| P000133 | The quantity control valve has an electrical fault or an open circuit. The off-time of the signal frequency is too long. |
| P000134 | The quantity control valve has an electrical fault or an open circuit. The on-time of the signal frequency is too short. |
| P000135 | The quantity control valve has an electrical fault or an open circuit. The on-time of the signal frequency is too long. |
| P000136 | The quantity control valve has an electrical fault or an open circuit. The signal frequency is too low. |
| P000137 | The quantity control valve has an electrical fault or an open circuit. The signal frequency is too high. |
| P000138 | The quantity control valve has an electrical fault or an open circuit. There is an incorrect signal frequency. |
| P000139 | The quantity control valve has an electrical fault or an open circuit. The signal has too few pulses. |
| P00013A | The quantity control valve has an electrical fault or an open circuit. The signal has too many pulses. |
| P00013B | The quantity control valve has an electrical fault or an open circuit. |
| P00013C | The quantity control valve has an electrical fault or an open circuit. |
| P00013D | The quantity control valve has an electrical fault or an open circuit. |
| P0001AB | The quantity control valve has an electrical fault or an open circuit. |
| P0001CD | Actuation of the radiator shutters has a malfunction. |
| P0001FC | The quantity control valve has an electrical fault or an open circuit. |
| P00DE00 | The temperature sensor for the coolant of the charge air cooler has an electrical fault. |
| P00DF00 | The temperature sensor for the coolant of the charge air cooler has a malfunction. |
| P00E000 | The temperature sensor for the coolant of the charge air cooler has a short circuit to ground. |
| P00E100 | The temperature sensor for the coolant of the charge air cooler has a short circuit to positive. |
| P011B00 | The coolant temperature is implausible relative to the intake air temperature. |
| P021800 | The transmission oil has overtemperature. |
| P02184B | The transmission oil has overtemperature. There is a fault due to overtemperature. |
| P022D13 | The output for bypass flap 2 'Charge air' has an electrical fault or an open circuit. There is an open circuit. |
| P022E11 | The output for bypass flap 2 'Charge air' has a short circuit to ground. There is a short circuit to ground. |
| P022F12 | The output for bypass flap 2 'Charge air' has a short circuit to positive. There is a short circuit to positive. |
| P026E71 | Actuation of the coolant pump of the charge air cooler has a malfunction. The actuator is blocked. |
| P026E7A | Actuation of the coolant pump of the charge air cooler has a malfunction. Leakage or a defective seal was detected. |
| P026E92 | Actuation of the coolant pump of the charge air cooler has a malfunction. The function or the instruction is faulty. |
| P040700 | The position sensor for the exhaust gas recirculation controller (cylinder bank 2) has a short circuit to ground. |
| P04070A | The position sensor for the exhaust gas recirculation controller (cylinder bank 2) has a short circuit to ground. |
| P040711 | The position sensor for the exhaust gas recirculation controller (cylinder bank 2) has a short circuit to ground. There is a short circuit to ground. |
| P040800 | The position sensor for the exhaust gas recirculation controller (cylinder bank 2) has a short circuit to positive. |
| P040809 | The position sensor for the exhaust gas recirculation controller (cylinder bank 2) has a short circuit to positive. There is a component fault. |
| P041B27 | Temperature sensor 2 of the exhaust gas recirculation has a malfunction. The signal change rate is above the permissible limit value. |
| P041B28 | Temperature sensor 2 of the exhaust gas recirculation has a malfunction. The signal offset is outside the permissible range. |
| P041B2A | Temperature sensor 2 of the exhaust gas recirculation has a malfunction. There is no signal change. |
| P041B62 | Temperature sensor 2 of the exhaust gas recirculation has a malfunction. The signal comparison is faulty. |
| P041C00 | Temperature sensor 2 of the exhaust gas recirculation has a short circuit to ground. |
| P041C11 | Temperature sensor 2 of the exhaust gas recirculation has a short circuit to ground. There is a short circuit to ground. |
| P041D00 | Temperature sensor 2 of the exhaust gas recirculation has a short circuit to positive. |
| P041D12 | Temperature sensor 2 of the exhaust gas recirculation has a short circuit to positive. There is a short circuit to positive. |
| P044A00 | The position sensor for exhaust gas recirculation controller 3 has an electrical fault. |
| P044B00 | The position sensor for exhaust gas recirculation controller 3 has a malfunction. |
| P044B26 | Differential pressure sensor 1 for exhaust gas recirculation (low pressure) has a malfunction. |
| P044B28 | Differential pressure sensor 1 for exhaust gas recirculation (low pressure) has a malfunction. |
| P044B64 | The position sensor for exhaust gas recirculation controller 3 has a malfunction. There is an implausible signal. |
| P044B81 | The position sensor for exhaust gas recirculation controller 3 has a malfunction. Incorrect data were received. |
| P044B96 | Differential pressure sensor 1 for exhaust gas recirculation (low pressure) has a malfunction. |
| P044C11 | Differential pressure sensor 1 for exhaust gas recirculation (low pressure) has a short circuit to ground. |
| P044D12 | Differential pressure sensor 1 for exhaust gas recirculation (low pressure) has a short circuit to positive. |
| P045A13 | The actuation for the exhaust gas recirculation controller (cylinder bank 2) has an electrical fault. There is an open circuit. |
| P045A4B | The actuation for the exhaust gas recirculation controller (cylinder bank 2) has an electrical fault. There is a fault due to overtemperature. |
| P045B00 | The actuation for the exhaust gas recirculation controller (cylinder bank 2) has a malfunction. |
| P045B11 | The actuation for the exhaust gas recirculation controller (cylinder bank 2) has a malfunction. There is a short circuit to ground. |
| P045B12 | The actuation for the exhaust gas recirculation controller (cylinder bank 2) has a malfunction. There is a short circuit to positive. |
| P045B28 | The actuation for the exhaust gas recirculation controller (cylinder bank 2) has a malfunction. The signal offset is outside the permissible range. |
| P045B4B | The actuation for the exhaust gas recirculation controller (cylinder bank 2) has a malfunction. There is a fault due to overtemperature. |
| P045B54 | The actuation for the exhaust gas recirculation controller (cylinder bank 2) has a malfunction. Calibration is missing. |
| P045B71 | The actuation for the exhaust gas recirculation controller (cylinder bank 2) has a malfunction. The actuator is blocked. |
| P045B75 | The actuation for the exhaust gas recirculation controller (cylinder bank 2) has a malfunction. The emergency position was not reached. |
| P045B77 | The actuation for the exhaust gas recirculation controller (cylinder bank 2) has a malfunction. The commanded position cannot be reached. |
| P045B78 | The actuation for the exhaust gas recirculation controller (cylinder bank 2) has a malfunction. The adaptation or adjustment is incorrect. |
| P045B79 | The actuation for the exhaust gas recirculation controller (cylinder bank 2) has a malfunction. The mechanical connection has failed. |
| P045B84 | The actuation for the exhaust gas recirculation controller (cylinder bank 2) has a malfunction. There is a signal below the permissible limit value. |
| P045B85 | The actuation for the exhaust gas recirculation controller (cylinder bank 2) has a malfunction. There is a signal above the permissible limit value. |
| P045B98 | The actuation for the exhaust gas recirculation controller (cylinder bank 2) has a malfunction. The component or the system has overtemperature. |
| P045C11 | The actuation for the exhaust gas recirculation controller (cylinder bank 2) has a short circuit to ground. There is a short circuit to ground. |
| P045D12 | The actuation for the exhaust gas recirculation controller (cylinder bank 2) has a short circuit to positive. There is a short circuit to positive. |
| P045E13 | The exhaust gas recirculation controller (cylinder bank 2) is jammed open. There is an open circuit. |
| P047513 | Exhaust gas recirculation actuator 1 (low pressure) has an electrical fault. There is an open circuit. |
| P047579 | Exhaust gas recirculation actuator 1 (low pressure) has an electrical fault. The mechanical connection has failed. |
| P047628 | Exhaust gas recirculation actuator 1 (low pressure) has a malfunction. The signal offset is outside the permissible range. |
| P04764B | Exhaust gas recirculation actuator 1 (low pressure) has a malfunction. There is a fault due to overtemperature. |
| P047671 | Exhaust gas recirculation actuator 1 (low pressure) has a malfunction. The actuator is blocked. |
| P047677 | Exhaust gas recirculation actuator 1 (low pressure) has a malfunction. The commanded position cannot be reached. |
| P047678 | Exhaust gas recirculation actuator 1 (low pressure) has a malfunction. The adaptation or adjustment is incorrect. |
| P047679 | Exhaust gas recirculation actuator 1 (low pressure) has a malfunction. The mechanical connection has failed. |
| P047692 | Exhaust gas recirculation actuator 1 (low pressure) has a malfunction. The function or the instruction is faulty. |
| P047698 | Exhaust gas recirculation actuator 1 (low pressure) has a malfunction. The component or the system has overtemperature. |
| P0476F0 | Exhaust gas recirculation actuator 1 (low pressure) has a malfunction. No normalizing. |
| P047700 | Exhaust gas recirculation actuator 1 has a short circuit to ground. |
| P04771C | Exhaust gas recirculation actuator 1 has a short circuit to ground. The voltage value is outside the permissible range. |
| P047800 | Exhaust gas recirculation actuator 1 has a short circuit to positive. |
| P04781C | Exhaust gas recirculation actuator 1 has a short circuit to positive. The voltage value is outside the permissible range. |
| P048000 | The output of electric fan 1 has an electrical fault or an open circuit. |
| P048013 | The output of electric fan 1 has an electrical fault or an open circuit. There is an open circuit. |
| P048300 | The electric fan has a malfunction. |
| P048304 | The electric fan has a malfunction. There is an internal fault. |
| P048392 | The electric fan has a malfunction. The function or the instruction is faulty. |
| P0483D5 | The electric fan has a malfunction. |
| P048A71 | The exhaust gas recirculation actuator (cylinder bank 1) is jammed closed. The actuator is blocked. |
| P048D00 | The position sensor or position switch for exhaust gas recirculation actuator 1 has a short circuit to ground. |
| P048E00 | The position sensor or position switch for exhaust gas recirculation actuator 1 has a short circuit to positive. |
| P053200 | The refrigerant pressure sensor has a short circuit to ground. |
| P053216 | The refrigerant pressure sensor has a short circuit to ground. The limit value for electrical voltage has not been attained. |
| P053300 | The refrigerant pressure sensor has a short circuit to positive. |
| P053317 | The refrigerant pressure sensor has a short circuit to positive. The limit value for electrical voltage has been exceeded. |
| P056000 | The on-board electrical system voltage has a malfunction. |
| P056016 | The on-board electrical system voltage has a malfunction. The limit value for electrical voltage has not been attained. |
| P056017 | The on-board electrical system voltage has a malfunction. The limit value for electrical voltage has been exceeded. |
| P056200 | The on-board power supply voltage is too low. |
| P056216 | The on-board power supply voltage is too low. The limit value for electrical voltage has not been attained. |
| P056300 | The on-board power supply voltage is too high. |
| P056317 | The on-board power supply voltage is too high. The limit value for electrical voltage has been exceeded. |
| P059F00 | Radiator shutter 1 does not close. |
| P059F01 | Radiator shutter 1 does not close. There is a general electrical fault. |
| P059F07 | Radiator shutter 1 does not close. There is a mechanical fault. |
| P059F92 | Radiator shutter 1 does not close. The function or the instruction is faulty. |
| P05AE00 | Radiator shutter 2 does not close. |
| P05AE01 | Radiator shutter 2 does not close. There is a general electrical fault. |
| P05AE07 | Radiator shutter 2 does not close. There is a mechanical fault. |
| P05AE09 | Radiator shutter 2 does not close. There is a component fault. |
| P05AE9A | Radiator shutter 2 does not close. The operating conditions for the component or the system are not satisfied. |
| P060100 | There is an internal control unit fault affecting the calculation of the checksum. |
| P060257 | The control unit is not programmed. Incorrect or incompatible software modules were detected. |
| P060400 | There is an internal control unit fault in the RAM memory. |
| P060545 | There is an internal control unit fault in the ROM memory. There is an error in the program memory. |
| P060546 | There is an internal control unit fault in the ROM memory. There is an error in the calibration or parameterization memory. |
| P062F00 | There is an internal error in the EEPROM of the control unit. |
| P063400 | The temperature in the control unit is too high. |
| P064500 | The output for the magnetic clutch of the air conditioning has a malfunction. |
| P064600 | The output for the magnetic clutch of the air conditioning has a short circuit to ground. |
| P064700 | The output for the magnetic clutch of the air conditioning has a short circuit to positive. |
| P064F00 | An unauthorized software calibration was detected. |
| P065100 | Output 2 for the reference voltage of the sensors has an electrical fault or an open circuit. |
| P065200 | Output 2 for the reference voltage of the sensors has a short circuit to ground. |
| P065300 | Output 2 for the reference voltage of the sensors has a short circuit to positive. |
| P065800 | The power supply to the actuators has a short circuit to ground. |
| P065900 | The power supply to the actuators has a short circuit to positive. |
| P066600 | The internal temperature sensor of the control unit has an electrical fault. |
| P066800 | The internal temperature sensor of the control unit has a short circuit to ground. |
| P066900 | The internal temperature sensor of the control unit has a short circuit to positive. |
| P068500 | The output for the relay 'Circuit 87 (combustion engine)' has an electrical fault or an open circuit. |
| P068600 | The output for relay 'Circuit 87 (combustion engine)' has a short circuit to ground. |
| P068700 | The output for relay 'Circuit 87 (combustion engine)' has a short circuit to positive. |
| P068916 | The input 'Circuit 87' (combustion engine) has a short circuit to ground. The limit value for electrical voltage has not been attained. |
| P068B00 | The relay 'Circuit 87 (combustion engine)' has shut off too late. |
| P069017 | The input 'Circuit 87' (combustion engine) has a short circuit to positive. The limit value for electrical voltage has been exceeded. |
| P069100 | The output of electric fan 1 has a short circuit to ground. |
| P069200 | The output of electric fan 1 has a short circuit to positive. |
| P069212 | The output of electric fan 1 has a short circuit to positive. There is a short circuit to positive. |
| P069214 | The output of electric fan 1 has a short circuit to positive. There is a short circuit to ground or an open circuit. |
| P069296 | The output of electric fan 1 has a short circuit to positive. There is an internal component fault. |
| P06A600 | Output 1 for the reference voltage of the sensors has a malfunction. |
| P06A700 | Output 2 for the reference voltage of the sensors has a malfunction. |
| P06A800 | Output 3 for the reference voltage of the sensors has a malfunction. |
| P06AD00 | Internal temperature sensor 2 of the control unit has a short circuit to ground. |
| P06AE00 | Internal temperature sensor 2 of the control unit has a short circuit to positive. |
| P06B800 | There is an internal control unit fault in the NVRAM memory. |
| P06F200 | The internal temperature sensor of control unit 'AdBlue®' has a short circuit to ground. |
| P06F300 | The internal temperature sensor of control unit 'AdBlue®' has a short circuit to positive. |
| P0A0000 | Coolant temperature sensor 1 has a malfunction. |
| P0A0101 | The temperature sensor for the low-temperature circuit has a malfunction. There is a general electrical fault. |
| P0A0116 | The temperature sensor for the low-temperature circuit has a malfunction. The limit value for electrical voltage has not been attained. |
| P0A0200 | The temperature sensor for the low-temperature circuit has a short circuit to ground. |
| P0A0300 | The temperature sensor for the low-temperature circuit has a short circuit to positive. |
| P0A0B00 | The interlock circuit of the high-voltage on-board electrical system has a malfunction. |
| P0A0C00 | The interlock circuit of the high-voltage on-board electrical system has a short circuit to ground. |
| P0A0D00 | The interlock circuit of the high-voltage on-board electrical system has a short circuit to positive. |
| P0A0E00 | The interlock circuit of the high-voltage on-board electrical system has a sporadic malfunction. |
| P0A3C00 | Inverter 'Electric machine A' has overtemperature. |
| P0A7D00 | The charge level of the high-voltage battery module is too low. |
| P0A9300 | The cooling system for the low temperature circuit has a malfunction. |
| P0A9301 | The cooling system for the low temperature circuit has a malfunction. There is a general electrical fault. |
| P0A934B | The cooling system for the low temperature circuit has a malfunction. There is a fault due to overtemperature. |
| P0A937A | The cooling system for the low temperature circuit has a malfunction. Leakage or a defective seal was detected. |
| P0A937B | The cooling system for the low temperature circuit has a malfunction. The fluid level is too low. |
| P0A9398 | The cooling system for the low temperature circuit has a malfunction. The component or the system has overtemperature. |
| P0A9400 | The control unit 'DC/DC converter' has a malfunction. |
| P0AB901 | The hybrid system has a malfunction. There is a general electrical fault. |
| P0AB902 | The hybrid system has a malfunction. There is a general signal fault. |
| P0AB903 | The hybrid system has a malfunction. There is a frequency or pulse width modulation fault. |
| P0AB904 | The hybrid system has a malfunction. There is an internal fault. |
| P0AB905 | The hybrid system has a malfunction. There is a programming fault. |
| P0AB906 | The hybrid system has a malfunction. There is an algorithm fault. |
| P0AB907 | The hybrid system has a malfunction. There is a mechanical fault. |
| P0AB90A | The hybrid system has a malfunction. On-board charger |
| P0AB90B | The hybrid system has a malfunction. On-board charger |
| P0AB90C | The hybrid system has a malfunction. On-board charger |
| P0AB90D | The hybrid system has a malfunction. On-board charger |
| P0AB90E | The hybrid system has a malfunction. On-board charger |
| P0AB90F | The hybrid system has a malfunction. On-board charger |
| P0AB910 | The hybrid system has a malfunction. Reserved for ISO/SAE |
| P0AB911 | The hybrid system has a malfunction. There is a short circuit to ground. |
| P0AB912 | The hybrid system has a malfunction. There is a short circuit to positive. |
| P0AB913 | The hybrid system has a malfunction. There is an open circuit. |
| P0AB914 | The hybrid system has a malfunction. There is a short circuit to ground or an open circuit. |
| P0AB915 | The hybrid system has a malfunction. There is a short circuit to positive or an open circuit. |
| P0AB916 | The hybrid system has a malfunction. The limit value for electrical voltage has not been attained. |
| P0AB917 | The hybrid system has a malfunction. The limit value for electrical voltage has been exceeded. |
| P0AB918 | The hybrid system has a malfunction. The limit value for current has not been attained. |
| P0AB919 | The hybrid system has a malfunction. The limit value for current has been exceeded. |
| P0AB920 | The hybrid system has a malfunction. Reserved for ISO/SAE |
| P0AB921 | The hybrid system has a malfunction. The signal amplitude is less than the minimum amplitude. |
| P0AB922 | The hybrid system has a malfunction. The signal amplitude is greater than the maximum amplitude. |
| P0AB926 | The hybrid system has a malfunction. The signal change rate is below the permissible limit value. |
| P0AB927 | The hybrid system has a malfunction. The signal change rate is above the permissible limit value. |
| P0AB929 | The hybrid system has a malfunction. There is an invalid signal. |
| P0AB92A | The hybrid system has a malfunction. There is no signal change. |
| P0AB92B | The hybrid system has a malfunction. The electrical lines have a short circuit to each other. |
| P0AB92C | The hybrid system has a malfunction. Battery management system |
| P0AB92D | The hybrid system has a malfunction. Battery management system |
| P0AB92E | The hybrid system has a malfunction. Battery management system |
| P0AB92F | The hybrid system has a malfunction. There is an erratic signal. |
| P0AB930 | The hybrid system has a malfunction. Reserved for ISO/SAE |
| P0AB931 | The hybrid system has a malfunction. The signal is not present. |
| P0AB932 | The hybrid system has a malfunction. The off-time of the signal frequency is too short. |
| P0AB933 | The hybrid system has a malfunction. The off-time of the signal frequency is too long. |
| P0AB934 | The hybrid system has a malfunction. The on-time of the signal frequency is too short. |
| P0AB935 | The hybrid system has a malfunction. The on-time of the signal frequency is too long. |
| P0AB936 | The hybrid system has a malfunction. The signal frequency is too low. |
| P0AB937 | The hybrid system has a malfunction. The signal frequency is too high. |
| P0AB938 | The hybrid system has a malfunction. There is an incorrect signal frequency. |
| P0AB939 | The hybrid system has a malfunction. The signal has too few pulses. |
| P0AB93A | The hybrid system has a malfunction. The signal has too many pulses. |
| P0AB93B | The hybrid system has a malfunction. Battery management system |
| P0AB93C | The hybrid system has a malfunction. Battery management system |
| P0AB93D | The hybrid system has a malfunction. On-board charger |
| P0AF700 | Control unit "DC/DC converter" has overtemperature. |
| P0AFA00 | The power supply of the high-voltage on-board electrical system is too low. |
| P0AFB00 | The power supply of the high-voltage on-board electrical system is too high. |
| P0C3100 | The cooling system for low temperature circuit B has a malfunction. |
| P0C3200 | The cooling system for the high-voltage battery has a malfunction. |
| P0C4200 | The coolant temperature sensor in the high-voltage battery module has an electrical fault. |
| P0C4300 | The coolant temperature sensor in the high-voltage battery module has a malfunction. |
| P0C4400 | The coolant temperature sensor in the high-voltage battery module has a short circuit to ground. |
| P0C4408 | The coolant temperature sensor in the high-voltage battery module has a short circuit to ground. There is a signal fault or the message is faulty. |
| P0C4500 | The coolant temperature sensor in the high-voltage battery module has a short circuit to positive. |
| P0C4507 | The coolant temperature sensor in the high-voltage battery module has a short circuit to positive. There is a mechanical fault. |
| P0C4600 | The coolant temperature sensor in the high-voltage battery module has a sporadic malfunction. |
| P0C4609 | The coolant temperature sensor in the high-voltage battery module has a sporadic malfunction. There is a component fault. |
| P0C4700 | The actuation of coolant pump A of the high-voltage battery module has an electrical fault or an open circuit. |
| P0C4800 | The actuation of coolant pump A of the high-voltage battery module has short circuit to ground. |
| P0C4900 | The actuation of coolant pump A of the high-voltage battery module has short circuit to positive. |
| P0C4A00 | The actuation of coolant pump A of the high-voltage battery module has a malfunction. |
| P0C4A4B | The actuation of coolant pump A of the high-voltage battery module has a malfunction. There is a fault due to overtemperature. |
| P0C4A7A | The actuation of coolant pump A of the high-voltage battery module has a malfunction. Leakage or a defective seal was detected. |
| P0C4A92 | The actuation of coolant pump A of the high-voltage battery module has a malfunction. The function or the instruction is faulty. |
| P0C7300 | Circulation pump 1 for the low-temperature circuit has a malfunction. |
| P0C744B | Circulation pump 2 for the low-temperature circuit has a malfunction. There is a fault due to overtemperature. |
| P0C7600 | The discharge time in the high-voltage on-board electrical system is too long. |
| P0C7700 | The precharging time of the high-voltage on-board electrical system is too short. |
| P0C7800 | The precharging time of the high-voltage on-board electrical system is too long. |
| P0CDF00 | Actuation "Shutoff valve for coolant of high-voltage battery module" has an electrical fault or open circuit. |
| P0CE000 | The shutoff valve for the coolant of the high-voltage battery module does not close. |
| P0CF300 | The electric circuit of the pilot function has an electrical fault or open circuit. |
| P0CF400 | The electric circuit of the pilot function has a malfunction. |
| P0CF600 | The electric circuit of the pilot function has a short circuit to positive. |
| P0CF900 | The internal switch for starting the charging process has a malfunction. |
| P0CFD00 | The internal switch for starting the charging process does not close. |
| P0CFE00 | The internal switch for starting the charging process does not open. |
| P0D1A00 | Actuation of the switchover valve in the coolant circuit of the high-voltage battery module has an electrical fault or open circuit. |
| P0D1A13 | Actuation of the switchover valve in the coolant circuit of the high-voltage battery module has an electrical fault or open circuit. There is an open circuit. |
| P0D1B00 | The switchover valve in the coolant circuit of the high-voltage battery module does not close. |
| P0D1B4B | The switchover valve in the coolant circuit of the high-voltage battery module does not close. There is a fault due to overtemperature. |
| P0D1D00 | Actuation of the switchover valve in the coolant circuit of the high-voltage battery module has a short circuit to ground. |
| P0D1E00 | Actuation of the switchover valve in the coolant circuit of the high-voltage battery module has a short circuit to positive. |
| P0D2000 | The output voltage of the charger integrated in the vehicle has a malfunction. |
| P0D2200 | The output current of the on-board charger has a malfunction. |
| P0D2400 | The temperature of the on-board charger is too high. |
| P0D2600 | The precharging time for the on-board charger is too long. |
| P0D2A00 | The input current of the on-board charger is too high. |
| P0D3900 | Sensor "Input current of on-board charger" has a malfunction. |
| P0D3A00 | The sensor 'Input current of on-board charger' has a short circuit to ground. |
| P0D3B00 | The sensor 'Input current of on-board charger' has a short circuit to positive. |
| P0D3D00 | The sensor 'Input voltage of on-board charger' has an electrical fault. |
| P0D3E00 | The sensor 'Input voltage of on-board charger' has a malfunction. |
| P0D3F00 | The sensor 'Input voltage of on-board charger' has a short circuit to ground. |
| P0D4000 | The sensor 'Input voltage of on-board charger' has a short circuit to positive. |
| P0D4D00 | The sensor 'Output voltage of on-board charger' has a malfunction. |
| P0D5200 | The sensor 'Output current of on-board charger' has a malfunction. |
| P0D5400 | The sensor 'Output current of on-board charger' has a short circuit to positive. |
| P0D5600 | The sensor for contact detection between the female contact and the charging cable has an electrical fault. |
| P0D5700 | The sensor for contact detection between the female contact and the charging cable has a malfunction. |
| P0D5800 | The sensor for contact detection between the female contact and the charging cable has a short circuit to ground. |
| P0D5900 | The sensor for contact detection between the female contact and the charging cable has a short circuit to positive. |
| P0D8600 | Charge level indicator RED of the on-board charger has an open circuit. |
| P0D8700 | Charge level indicator RED of the on-board charger has a short circuit to ground. |
| P0D8800 | Charge level indicator RED of the on-board charger has a short circuit to positive. |
| P0D8900 | Charge level indicator GREEN of the on-board charger has an open circuit. |
| P0D8A00 | Charge level indicator GREEN of the on-board charger has a short circuit to ground. |
| P0D8B00 | Charge level indicator GREEN of the on-board charger has a short circuit to positive. |
| P0D8F00 | The cooling of the on-board charger is inadequate. |
| P0D9100 | The lock for the charging cable has an open circuit. |
| P0D9200 | The lock for the charging cable has a short circuit to ground. |
| P0D9300 | The lock for the charging cable has a short circuit to positive. |
| P0D9500 | The release for the charging cable has an open circuit. |
| P0D9600 | The release for the charging cable has a short circuit to ground. |
| P0D9700 | The release for the charging cable has a short circuit to positive. |
| P0D9900 | Temperature sensor of the female contact has an electrical fault. |
| P0D9A00 | The temperature sensor of the female contact has a malfunction. |
| P0D9B00 | Temperature sensor of female contact has a short circuit to ground. |
| P0D9C00 | Temperature sensor of female contact has a short circuit to positive. |
| P0D9D00 | The temperature sensor of the female contact has a sporadic malfunction. |
| P0D9F00 | Position sensor "Charging cable lock" has a malfunction. |
| P0E1300 | Electric heater booster A for the coolant of the high-voltage battery module has a short circuit to ground. |
| P0E1320 | Electric heater booster A for the coolant of the high-voltage battery module has a short circuit to ground. Reserved for ISO/SAE |
| P0E1400 | Electric heater booster A for the coolant of the high-voltage battery module has a short circuit to positive. |
| P0E1421 | Electric heater booster A for the coolant of the high-voltage battery module has a short circuit to positive. The signal amplitude is less than the minimum amplitude. |
| P0E1500 | Electric heater booster A for the coolant of the high-voltage battery module has a malfunction. |
| P0E157A | Electric heater booster A for the coolant of the high-voltage battery module has a malfunction. Leakage or a defective seal was detected. |
| P0E1596 | Electric heater booster A for the coolant of the high-voltage battery module has a malfunction. There is an internal component fault. |
| P0E1A00 | Actuation of coolant pump B of the high-voltage battery module has an electrical fault or open circuit. |
| P0E1D7A | The actuation of coolant pump B of the high-voltage battery module has a malfunction. Leakage or a defective seal was detected. |
| P0E1D92 | The actuation of coolant pump B of the high-voltage battery module has a malfunction. The function or the instruction is faulty. |
| P0E214B | The output of the switchover valve in the coolant circuit of the high-voltage battery module has overtemperature. There is a fault due to overtemperature. |
| P0E3C00 | The speed of coolant pump A of the high-voltage battery module has a malfunction. |
| P0E5E00 | The processor in the on-board charger has a malfunction. |
| P0E5F00 | The temperature at the plug of the charging cable is too high. |
| P0E6000 | The charge control system in the on-board charger has a malfunction. |
| P0EA700 | Additional low-temperature circuit 2 has a malfunction. |
| P0EA727 | Additional low-temperature circuit 2 has a malfunction. The signal change rate is above the permissible limit value. |
| P0EA74B | Additional low-temperature circuit 2 has a malfunction. There is a fault due to overtemperature. |
| P0EA792 | Additional low-temperature circuit 2 has a malfunction. The function or the instruction is faulty. |
| P0EA798 | Additional low-temperature circuit 2 has a malfunction. The component or the system has overtemperature. |
| P0EBC00 | Sensor 1 for the refrigerant temperature has an electrical fault. |
| P0EBD00 | Sensor 1 for the refrigerant temperature has a short circuit to positive. |
| P0EBE00 | Sensor 1 for the refrigerant temperature has a short circuit to ground. |
| P0EBF27 | Sensor 1 for the refrigerant temperature has a malfunction. The signal change rate is above the permissible limit value. |
| P0EBF64 | Sensor 1 for the refrigerant temperature has a malfunction. There is an implausible signal. |
| P0EC900 | The switchover valve for the refrigerant for high-voltage battery cooling is stuck open. |
| P109587 | There is currently no further information available on this fault code. |
| P121D87 | Communication with the coolant pump of low-temperature circuit 1 has a malfunction. The message is missing. |
| P126F11 | The signal 'Hot start' from the automatic engine start/stop system has a malfunction. There is a short circuit to ground. |
| P126F62 | The signal 'Hot start' from the automatic engine start/stop system has a malfunction. The signal comparison is faulty. |
| P126F64 | The signal 'Hot start' from the automatic engine start/stop system has a malfunction. There is an implausible signal. |
| P13B100 | The output for on-board electrical system switchover has an electrical fault or an open circuit. |
| P13B700 | The electricity contract certificate was not found or is invalid. |
| P13C200 | The exhaust flap has a malfunction. |
| P13C21E | The exhaust flap has a malfunction. The resistance value is outside the permissible range. |
| P13C228 | The exhaust flap has a malfunction. The signal offset is outside the permissible range. |
| P13C24B | The exhaust flap has a malfunction. There is a fault due to overtemperature. |
| P13C271 | The exhaust flap has a malfunction. The actuator is blocked. |
| P13C275 | The exhaust flap has a malfunction. The emergency position was not reached. |
| P13C284 | The exhaust flap has a malfunction. There is a signal below the permissible limit value. |
| P13C285 | The exhaust flap has a malfunction. There is a signal above the permissible limit value. |
| P13C298 | The exhaust flap has a malfunction. The component or the system has overtemperature. |
| P13C700 | The exhaust flap has an electrical fault or an open circuit. |
| P13C800 | The exhaust flap has a short circuit to positive. |
| P13C900 | The exhaust flap has a short circuit to ground. |
| P13D900 | The lock of the socket flap has an open circuit. |
| P13DA00 | The lock of the socket flap has a short circuit to ground. |
| P13DB00 | The lock of the socket flap has a short circuit to positive. |
| P13E800 | The lock for the charging cable is jammed open. |
| P13E900 | The lock for the charging cable is jammed closed. |
| P13EB00 | The master certificate for communication with the Vehicle Homepage has an internal fault. |
| P140100 | The output for relay 'Circuit 87C (drivetrain control unit)' has an electrical fault or open circuit. |
| P144100 | The coolant pump of low-temperature circuit 1 for charge air and transmission cooling has a malfunction. |
| P144200 | The three-disk thermostat in low-temperature circuit 2 on plug-in hybrid vehicles has a malfunction. |
| P144300 | The circulation pump for coolant in low-temperature circuit 2 on plug-in hybrid vehicles has a malfunction. |
| P144400 | The temperature sensor of the refrigerant circuit on plug-in hybrid vehicles has a malfunction. |
| P144500 | The temperature sensor of low-temperature circuit 2 on plug-in hybrid vehicles has a malfunction. |
| P144501 | The temperature sensor of low-temperature circuit 2 on plug-in hybrid vehicles has a malfunction. There is a general electrical fault. |
| P144E00 | The valve 'Low temperature circuit 2 via heat exchanger in refrigerant circuit' has a malfunction. |
| P145C00 | Communication with the control unit 'DISTRONIC' has a malfunction. |
| P150864 | Differential pressure sensor 2 for exhaust gas recirculation has a malfunction. There is an implausible signal. |
| P150C00 | The output for the expansion valve in refrigerant circuit 'Cooling' has a malfunction. |
| P150C11 | The output for the expansion valve in refrigerant circuit 'Cooling' has a malfunction. There is a short circuit to ground. |
| P150C12 | The output for the expansion valve in refrigerant circuit 'Cooling' has a malfunction. There is a short circuit to positive. |
| P150C13 | The output for the expansion valve in refrigerant circuit 'Cooling' has a malfunction. There is an open circuit. |
| P150D11 | The exhaust gas recirculation controller has a malfunction. There is a short circuit to ground. |
| P150D12 | The exhaust gas recirculation controller has a malfunction. There is a short circuit to positive. |
| P150E11 | The output for relay 'Circuit 87C' has a malfunction. There is a short circuit to ground. |
| P150E12 | The output for relay 'Circuit 87C' has a malfunction. There is a short circuit to positive. |
| P150E16 | The output for relay 'Circuit 87C' has a malfunction. The limit value for electrical voltage has not been attained. |
| P150E17 | The output for relay 'Circuit 87C' has a malfunction. The limit value for electrical voltage has been exceeded. |
| P150F00 | Relay 'Circuit 87C"" has shut off too late. |
| P161400 | An internal control unit reset was performed. |
| P167B00 | The drivetrain has been switched off due to a crash signal. |
| P16F000 | The internal communication of the control unit has a malfunction. |
| P180000 | The control unit has a malfunction. |
| P180500 | The hardware monitoring function has detected a fault in the control unit. |
| P1C4000 | Communication with the coolant pump of the high-voltage battery module has a malfunction. |
| P1C4087 | Communication with the coolant pump of the high-voltage battery module has a malfunction. The message is missing. |
| P1C7000 | The contact of the ground strap is faulty. |
| P1C8000 | The high-voltage component lockout is active. |
| P1CB400 | The power supply for circuit 30c has a malfunction. |
| P1CB600 | The power supply for circuit 30c is too high. |
| P1CB700 | The power supply for circuit 30c is too low. |
| P1CB800 | The power supply for circuit 30c is implausible. |
| P1D0800 | The internal DC voltage of the on-board charger is too low. |
| P1D0900 | The internal DC voltage of the on-board charger is too high. |
| P1D0C00 | The temperature of the on-board charger is too low. |
| P1D1E00 | The temperature sensor for the refrigerant of the high-voltage battery has a short circuit to ground. |
| P1D1F00 | The temperature sensor for the refrigerant of the high-voltage battery has a short circuit to positive. |
| P1D2000 | The temperature sensor for the refrigerant of the high-voltage battery has a sporadic malfunction. |
| P1D2E00 | The internal sensor 'Voltage of on-board charger' has a short circuit to ground. |
| P1D2F00 | The internal sensor 'Voltage of on-board charger' has a short circuit to positive. |
| P1D3D00 | Temperature sensor "DC/DC converter of on-board charger" has a short circuit to ground. |
| P1D3E00 | Temperature sensor "DC/DC converter of on-board charger" has a short circuit to positive. |
| P1D4000 | The internal power supply of the on-board charger is too low. |
| P1D4100 | The internal power supply of the on-board charger is too high. |
| P1D4B00 | The internal power supply of the control unit is implausible. |
| P1D4D00 | The internal power supply of the components (direct current) of the on-board charger is too low. |
| P1D4E00 | The internal power supply of the components (direct current) of the on-board charger is too high. |
| P1D4F00 | The internal power supply of the components (direct current) of the on-board charger is implausible. |
| P1D5100 | The internal power supply of the components (alternating current) of the on-board charger is too low. |
| P1D5200 | The internal power supply of the components (alternating current) of the on-board charger is too high. |
| P1D5300 | The internal power supply of the components (alternating current) of the on-board charger is implausible. |
| P1D5600 | Current sensor A of the power factor correction module of the on-board charger has a short circuit to ground. |
| P1D5700 | Current sensor A of the power factor correction module of the on-board charger has a short circuit to positive. |
| P1D5B00 | Current sensor B of the power factor correction module of the on-board charger has a short circuit to ground. |
| P1D5C00 | Current sensor B of the power factor correction module of the on-board charger has a short circuit to positive. |
| P1D6100 | Current sensor A of the DC/DC converter of the on-board charger has a short circuit to positive. |
| P1D6600 | Current sensor B of the DC/DC converter of the on-board charger has a short circuit to positive. |
| P1D8800 | A coolant loss was detected in low-temperature circuit 1. |
| P1D8900 | A coolant loss was detected in low-temperature circuit 2. |
| P1D897A | A coolant loss was detected in low-temperature circuit 2. Leakage or a defective seal was detected. |
| P1D8A11 | The refrigerant temperature sensor of the high-voltage battery has a malfunction. There is a short circuit to ground or an open circuit. |
| P1D8A16 | The refrigerant temperature sensor of the high-voltage battery has a malfunction. There is a signal below the permissible limit value. |
| P1D8A17 | The refrigerant temperature sensor of the high-voltage battery has a malfunction. There is a signal above the permissible limit value. |
| P1D8B00 | Coolant pump A of the high-voltage battery module has a malfunction. |
| P1D8C00 | The switchover valve of low-temperature circuit 1 has a malfunction. |
| P1D8C1D | The switchover valve of low-temperature circuit 1 has a malfunction. The current value is outside the permissible range. |
| P1D8C92 | The switchover valve of low-temperature circuit 1 has a malfunction. The function or the instruction is faulty. |
| P1D8F00 | Temperature sensor 2 for the low-temperature circuit has a malfunction. |
| P1D9000 | The matching of hardware and software is faulty. |
| P1D9100 | The refrigerant temperature sensor of the high-voltage battery has a malfunction. |
| P1D9200 | A fault was detected in low-temperature circuit 1 due to an implausible charge air temperature. |
| P1D9217 | A fault was detected in low-temperature circuit 1 due to an implausible charge air temperature. The limit value for electrical voltage has been exceeded. |
| P1D9264 | A fault was detected in low-temperature circuit 1 due to an implausible charge air temperature. There is an implausible signal. |
| P1D9300 | A fault was detected in low-temperature circuit 1 due to an implausible transmission oil temperature. |
| P1D934B | A fault was detected in low-temperature circuit 1 due to an implausible transmission oil temperature. There is a fault due to overtemperature. |
| P20B100 | The output for the coolant shutoff valve has an electrical fault or an open circuit. |
| P218100 | The cooling system has a malfunction. |
| P260179 | The output for the circulation pump 'Coolant' has a malfunction or does not switch off. The mechanical connection has failed. |
| P26017A | The output for the circulation pump 'Coolant' has a malfunction or does not switch off. Leakage or a defective seal was detected. |
| P260192 | The output for the circulation pump 'Coolant' has a malfunction or does not switch off. The function or the instruction is faulty. |
| P261100 | The regulating valve for climate control has a malfunction. |
| P261200 | The regulating valve for climate control has a short circuit to ground. |
| P261300 | The regulating valve for climate control has a short circuit to positive. |
| P26CB92 | The electric fan has a malfunction. There is an internal fault. |
| P26CB96 | The electric fan has a malfunction. There is an internal fault. |
| P26CE00 | The electric fan has a malfunction. Engine overspeed |
| U000187 | Drive train CAN communication has a malfunction. The message is missing. |
| U002888 | Communication with the drivetrain CAN bus has a malfunction. Bus OFF |
| U003788 | Communication with the chassis CAN bus has a malfunction. Bus OFF |
| U004688 | Communication with the drive train sensor CAN bus has a malfunction. Bus OFF |
| U005500 | Communication with the hybrid CAN bus has a malfunction. |
| U005588 | Communication with the hybrid CAN bus has a malfunction. Bus OFF |
| U006488 | Communication with the user interface CAN bus has a malfunction. Bus OFF |
| U007300 | Drive train CAN bus OFF fault |
| U007400 | Chassis CAN bus OFF fault |
| U008088 | Communication with the engine CAN bus has a malfunction. Bus OFF |
| U010000 | Communication with the control unit 'combustion engine' has a malfunction. |
| U010086 | Communication with the control unit 'combustion engine' has a malfunction. There is an incorrect signal. |
| U010087 | Communication with the control unit 'combustion engine' has a malfunction. The message is missing. |
| U010100 | Communication with control unit "Transmission" has a malfunction. |
| U010187 | Communication with control unit "Transmission" has a malfunction. The message is missing. |
| U010300 | Communication with the electronic selector lever module has a malfunction. |
| U010387 | Communication with the electronic selector lever module has a malfunction. The message is missing. |
| U010987 | Communication with control unit "Fuel pump" has a malfunction. The message is missing. |
| U011100 | Communication with control unit "Battery" has a malfunction. |
| U011187 | Communication with control unit "Battery" has a malfunction. The message is missing. |
| U011200 | Communication with control unit 'High-voltage battery' has a malfunction. |
| U011287 | Communication with control unit 'High-voltage battery' has a malfunction. The message is missing. |
| U011500 | Communication with control unit 'Drivetrain' has a malfunction. |
| U012100 | Communication with ESP has a malfunction. |
| U012200 | Communication with control unit 'Traction system' has a malfunction. |
| U012287 | Communication with control unit 'Traction system' has a malfunction. The message is missing. |
| U012300 | Implausible data were received from the instrument cluster. |
| U013C87 | Communication with the control unit 'Haptic accelerator pedal module' has a malfunction. The message is missing. |
| U014000 | Communication with the signal acquisition and actuation module has a malfunction. |
| U014087 | Communication with the signal acquisition and actuation module has a malfunction. The message is missing. |
| U014700 | Communication with control unit 'Audio or COMMAND' has a malfunction. |
| U014787 | Communication with control unit 'Audio or COMMAND' has a malfunction. The message is missing. |
| U015400 | Communication with control unit "Weight sensing system" has a malfunction. |
| U015487 | Communication with control unit "Weight sensing system" has a malfunction. The message is missing. |
| U015500 | Communication with the instrument cluster has a malfunction. |
| U015587 | Communication with the instrument cluster has a malfunction. The message is missing. |
| U015800 | Communication with control unit 'Head-up display' has a malfunction. |
| U016400 | Communication with the air conditioning has a malfunction. |
| U016487 | Communication with the air conditioning has a malfunction. The message is missing. |
| U016687 | Communication with control unit "Stationary heater" has a malfunction. The message is missing. |
| U016800 | Communication with the electronic ignition lock has a malfunction. |
| U016887 | Communication with the electronic ignition lock has a malfunction. The message is missing. |
| U016B87 | Communication with control unit 'Electric A/C compressor' has a malfunction. The message is missing. |
| U019B00 | Communication with the on-board charger has a malfunction. |
| U019B87 | Communication with the on-board charger has a malfunction. The message is missing. |
| U019F87 | There is currently no further information available on this fault code. |
| U01B000 | Communication with the hardware monitoring function of the high-voltage battery has a malfunction. |
| U021200 | Communication with the steering column module has a malfunction. |
| U021287 | Communication with the steering column module has a malfunction. The message is missing. |
| U028487 | Communication with radiator shutter 1 has a malfunction. The message is missing. |
| U028587 | Communication with radiator shutter 2 has a malfunction. The message is missing. |
| U028787 | Communication with control unit "Electric cooling pump" has a malfunction. The message is missing. |
| U029200 | Communication with control unit "Electric machine B" has a malfunction. |
| U029287 | Communication with control unit "Electric machine B" has a malfunction. The message is missing. |
| U029800 | Communication with control unit "DC/DC converter" has a malfunction. |
| U029887 | Communication with control unit "DC/DC converter" has a malfunction. The message is missing. |
| U02A687 | Communication with control unit 'Communications module' has a malfunction. The message is missing. |
| U02A900 | Communication with coolant pump 1 of the charge air cooler has a malfunction. |
| U02A987 | Communication with coolant pump 1 of the charge air cooler has a malfunction. The message is missing. |
| U030000 | An internal fault has occurred in the control unit software. |
| U040100 | Implausible data were received from control unit 'combustion engine'. |
| U040108 | Implausible data were received from control unit 'combustion engine'. There is a signal fault or the message is faulty. |
| U040186 | Implausible data were received from control unit 'combustion engine'. There is an incorrect signal. |
| U040200 | Implausible data were received from control unit 'Transmission'. |
| U040208 | Implausible data were received from control unit 'Transmission'. There is a signal fault or the message is faulty. |
| U040286 | Implausible data were received from control unit 'Transmission'. There is an incorrect signal. |
| U040400 | Implausible data were received from the electronic selector lever module. |
| U040408 | Implausible data were received from the electronic selector lever module. There is a signal fault or the message is faulty. |
| U041200 | Implausible data were received from control unit "Battery". |
| U041208 | Implausible data were received from control unit "Battery". There is a signal fault or the message is faulty. |
| U041500 | Implausible data were received from control unit 'ESP®'. |
| U041600 | Implausible data were received from control unit 'Traction system'. |
| U041608 | Implausible data were received from control unit 'Traction system'. There is a signal fault or the message is faulty. |
| U042300 | Implausible data were received from the instrument cluster. |
| U042308 | Implausible data were received from the instrument cluster. There is a signal fault or the message is faulty. |
| U042400 | Implausible data were received from the air conditioning. |
| U042408 | Implausible data were received from the air conditioning. There is a signal fault or the message is faulty. |
| U042486 | Implausible data were received from the air conditioning. There is an incorrect signal. |
| U042700 | Implausible data were received from the electronic ignition lock. |
| U042708 | Implausible data were received from the electronic ignition lock. There is a signal fault or the message is faulty. |
| U042900 | Implausible data were received from the steering column module. |
| U042908 | Implausible data were received from the steering column module. There is a signal fault or the message is faulty. |
| U045687 | There is currently no further information available on this fault code. |
| U059300 | Implausible data were received from control unit "Electric machine B". |
| U059308 | Implausible data were received from control unit "Electric machine B". There is a signal fault or the message is faulty. |
| U059387 | Implausible data were received from control unit "Electric machine B". The message is missing. |
| U062387 | There is currently no further information available on this fault code. |
| U062A87 | There is currently no further information available on this fault code. |
| U100887 | LIN bus 1 has a malfunction. The message is missing. |
| U103B00 | LIN bus 3 has a malfunction. |
| U104100 | Communication with the engine CAN bus has a malfunction. |
| U104300 | Communication with the peripheral CAN bus has a malfunction. |
| U109500 | Communication with the coolant pump of the charge air cooler has a malfunction. |
| U109587 | Communication with the coolant pump of the charge air cooler has a malfunction. The message is missing. |
| U113E00 | Communication with the battery sensor has a malfunction. |
| U113E87 | Communication with the battery sensor has a malfunction. The message is missing. |
| U118F00 | Communication with the control unit for telematics services has a malfunction. |
| U118F87 | Communication with the control unit for telematics services has a malfunction. The message is missing. |
| U11BE00 | Communication with the radiator shutters has a malfunction. |
| U11BE92 | Communication with the radiator shutters has a malfunction. The function or the instruction is faulty. |
| U11C800 | Communication of the on-board charger with control unit 'Traction system' has a malfunction. |
| U121800 | Communication with actuator motor "Switchover valve of low-temperature circuit 1" has a malfunction. |
| U121887 | Communication with actuator motor "Switchover valve of low-temperature circuit 1" has a malfunction. The message is missing. |
| U121987 | Communication with control unit 'Communications module' has a malfunction. The message is missing. |
| U121A00 | Communication with control unit "Fan" has a malfunction. |
| U121A87 | Communication with control unit "Fan" has a malfunction. The message is missing. |
| U121B00 | Communication with the control unit 'Haptic accelerator pedal module' has a malfunction. |
| U121C00 | Communication with actuator motor "Radiator shutters" has a malfunction. |
| U121D87 | Communication with the coolant pump of the low-temperature circuit has a malfunction. The message is missing. |
| U145C00 | Implausible data were received from the control unit 'DISTRONIC'. |
| U145C08 | Implausible data were received from the control unit 'DISTRONIC'. There is a signal fault or the message is faulty. |
| U151600 | Communication with the control unit 'DISTRONIC' has a malfunction. |
| U151601 | Communication with the control unit 'DISTRONIC' has a malfunction. There is a general electrical fault. |
| U151602 | Communication with the control unit 'DISTRONIC' has a malfunction. There is a general signal fault. |
| U151603 | Communication with the control unit 'DISTRONIC' has a malfunction. There is a frequency or pulse width modulation fault. |
| U151604 | Communication with the control unit 'DISTRONIC' has a malfunction. There is an internal fault. |
| U151605 | Communication with the control unit 'DISTRONIC' has a malfunction. There is a programming fault. |
| U151687 | Communication with the control unit 'DISTRONIC' has a malfunction. The message is missing. |
| U300100 | The control unit has performed a watchdog reset. |
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.