2002 Mercedes Benz SL600FACTORY OEM SERVICE PROCEDURE

Testing Procedure

NOTE: For ME-SFI control module location and identification, see ME-SFI CONTROL MODULE CONNECTOR IDENTIFICATION  .

O2 Signal -  Connect DVOM between right cylinder bank ME-SFI control module connector 1 terminals No. 40 and 42 (socket box terminals No. 40 and 42). Start engine and idle. Keep engine speed between 2000-3000 RPM for approximately 2 minutes after engine coolant temperature reaches more than 176°F (80°C). Allow engine to idle. Voltage must exceed or drop to less than 450-500 millivolts within one minute. If voltage is okay, test is complete. If voltage is not okay, possible causes are right O2 sensor (after TWC) heater failure, wiring harness failure, defective right O2 sensor (after TWC - G3/6) or defective right cylinder bank ME-SFI control module (N3/12). To check right O2 sensor (after TWC) heater failure, go to DTC P0141: O2 SENSOR HEATER OF RIGHT O2 SENSOR DOWNSTREAM TWC (G3/6)  .

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.