2002 Mercedes Benz G500FACTORY OEM SERVICE PROCEDURE

Testing Procedure

  1. CAN Data Bus -Β  Connect DVOM between ME-SFI control module connector "D" terminal No. 11 and 12 (socket box terminals No. 43 and 44). Turn ignition off. Resistance should be 55-65 ohms. If resistance is within specification, go to next step. If resistance is not within specification, possible causes are Controller Area Network (CAN) failure. Go to next step.
  2. Turn ignition off. Disconnect ME-SFI control module connector "D". Connect DVOM between ME-SFI control module connector "D" terminals No. 11 and No. 12 (socket box terminals No. 43 and 44). Resistance should be 115-125 ohms. If resistance is within specification, go to next step. If resistance is not within specification, possible causes are wiring harness failure or defective infrared DAS control module (N54/1). Repair as necessary.
  3. Turn ignition off. Disconnect ME-SFI control module connector "D" from test cable (socket box) and reconnect to ME-SFI control module. Connect DVOM between ME-SFI control module connector "D" terminals No. 11 and No. 12 (socket box terminals No. 43 and 44). Resistance should be 115-125 ohms. If resistance is within specification, test is complete. If resistance is not within specification, possible cause is ME-SFI control module (N3/10) defective. Repair as necessary.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.