2001 Mercedes Benz SL600FACTORY OEM SERVICE PROCEDURE

Testing Procedure

NOTE: For ME-SFI control module location and identification, see ME-SFI CONTROL MODULE CONNECTOR IDENTIFICATION  .

O2 Signal -  Connect DVOM between left cylinder bank ME-SFI control module connector 1 terminals No. 40 and 41 (socket box terminals No. 40 and 41). Start engine and idle. Allow engine to idle for at least 2 minutes after engine coolant temperature reaches more than 176°F (80°C). Voltage should fluctuate by more than 0.3 volts between -0.2 volts and one volt. If voltage is okay, test is complete. If voltage is not okay, possible causes are left O2 sensor (before TWC) heater failure, wiring harness failure or defective left O2 sensor (before TWC - G3/3). To check left O2 sensor (before TWC) heater failure, go to DTC P0155: O2 SENSOR HEATING OF LEFT O2 SENSOR UPSTREAM TWC (G3/3)  .

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.