2000 Mercedes Benz ML430FACTORY OEM SERVICE PROCEDURE

Wiring Continuity

  1. Connect voltmeter between generator B+ terminal and ground. Voltmeter should indicate battery voltage. If battery voltage is not indicated, check battery and check wiring between generator and battery for corrosion, loose terminals, etc.
  2. Turn ignition on and ensure instrument cluster charge indicator light (battery symbol) comes on (if equipped). If light does not come on, check wiring between generator and warning light, including indicator bulb.