1996 Mercedes Benz SL320FACTORY OEM SERVICE PROCEDURE

Test 4: RCL Receiver Remote Signal

Using Adapter Cable (202 589 15 63 00), connect Breakout Box (124 589 00 21 00) to remote control locking control module. See Figure . Measure voltage between terminals No. 1 and 7 at breakout box. Lock vehicle using remote transmitter. After vehicle completes locking and transmitter button is still depressed, .3-1 volt should exist. After vehicle completes locking and transmitter button is released, .3-1 volt should exist. If voltage is as specified, RCL receiver remote signal is okay at this time. If voltage is not as specified, check the following and repair as necessary:

  • Check wiring. See WIRING DIAGRAMSΒ  .
  • Replace RCL transmitter.
  • Replace RCL receiver.
Factory Service Tools