1988 Mercedes Benz 560SLFACTORY OEM SERVICE PROCEDURE

Switchover Valves

  1. Connect a multimeter to connector of switchover valves and measure voltage at 1200 RPM. Voltage should be about 12 volts. If voltage is okay, go to next test. If test is not okay, test electrical activation and replace control unit if necessary.
  2. Connect vacuum tester with "Y" fitting to switchover valve and check vacuum at 1200 RPM (switchover valve energized with 12 volts). Switchover should have about 19 in. Hg. If test is okay, test is complete. If test is not okay, test vacuum pump and replace switchover valve if necessary.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.