1987 Mercedes Benz 560SLFACTORY OEM SERVICE PROCEDURE
System Check
- With engine at operating temperature, disconnect coolant temperature sensor plug and attach a 2.5-ohm test resistor to simulate +68Β°F (+20Β°C). Disconnect vacuum line from side connection of switchover valve and connect vacuum tester with "Y" fitting. Start engine. Disconnect suction hose to air pump at air filter and close with finger.
- Air pump should be running and vacuum present (about 20 in. Hg). Suction should be felt at end of hose to air pump. If okay, go to next step. If not okay, go to step 4).
- Air pump should disengage approximately 60 seconds and vacuum must drop to zero. If it does, system okay. If not, unplug injection relay. Vacuum should drop. If okay, replace air injection relay. If not okay, check routing of vacuum lines and/or switchover valve.
- Unplug air injection relay. Check voltage between terminals No. 4 and 5 at plug. Voltage should be about 12 volts. If not okay, check power supply and ground wiring. Check air shutoff valve function and air hoses for proper routing. If okay, go to next step.
- Check voltage between terminals No. 3 and 1 at plug. Voltage should be about 12 volts. If okay, replace air injection relay. If not okay, check power supply.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.