2021 Mazda CX-9 Carbon Edition, AWDFACTORY OEM SERVICE PROCEDURE

Heated Oxygen Sensor (Ho2S) Removal/Installation: 2WD

G11436107Courtesy of MAZDA MOTORS CORP.
  1. Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION .)
  2. Lift up the vehicle.
  3. Remove the following parts:
    1. Plate (See EXHAUST SYSTEM REMOVAL/INSTALLATION .)
    2. Floor under cover (See FLOOR UNDER COVER REMOVAL/INSTALLATION .)
    3. Brace bar (See EXHAUST SYSTEM REMOVAL/INSTALLATION .)
  4. Disconnect the HO2S connector.
    Fig 1: Heated Oxygen Sensor, Connector, Clip And Nut With Torque Specification (2WD)
    G11436108Courtesy of MAZDA MOTORS CORP.
  5. Remove the clip B from the body.
  6. Remove the nut.
  7. Remove the clip A from the bracket.
  8. Remove the HO2S using the SST.
    Fig 2: Heated Oxygen Sensor With Torque Specification (2WD)
    G11436109Courtesy of MAZDA MOTORS CORP.
  9. Install in the reverse order of removal.