2021 Mazda CX-3 AWDFACTORY OEM SERVICE PROCEDURE

Fan Control Module Inspection

WARNING: This page is about a different car, the 2016 Mazda CX-3. However, it is still accessible from the selected car via links, so may be relevant.
  1. Connect the M-MDS to the DLC-2.
  2. Start and warm up the engine.
  3. Monitor the engine coolant temperature with the M-MDS.
  4. Measure the voltage at terminal A of the fan control module connector (3 terminals) as shown in the figure.
    Fig 1: Identifying Fan Control Module Connector 3 Terminals
    G10968787Courtesy of MAZDA MOTORS CORP.
    • If not within the specification, inspect the input signals from the following parts. If all the following parts are normal, replace the fan control module. (See COOLING FAN MOTOR REMOVAL/INSTALLATION .)
      • Engine Coolant Temperature (ECT) sensor
      • Refrigerant pressure sensor
      • Battery
      • DSC (HU/CM)
FAN CONTROL MODULE SPECIFICATION (A/C OFF)

Inspection Result
Engine coolant temperature (°C {°F}) PID FAN DUTY (%) Voltage (V)
100 30 3.6
100-106 {212-222} 30-75 3.6-9.0
106-108 {223-226} 75 9.0
more than 108 100 0.4 lower than battery voltage
FAN CONTROL MODULE SPECIFICATION (A/C ON; ENGINE COOLANT TEMPERATURE LESS THAN 98 °C - 208 °F AND IDLING)

Inspection Result
Refrigerant pressure (MPa {kgf/cm2 , psi}) PID FAN DUTY (%) Voltage (V)
less than 1.0 {10, 145} 30 3.6
1.0-1.7 {11-17, 146-246} 30-75 3.6-9.0
1.7-1.9 {18-19, 247-275} 75 9.0
more than 1.9 {19, 276} 100 0.4 lower than battery voltage
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.