2020 Mazda CX-30 Base, AWDFACTORY OEM SERVICE PROCEDURE

PID/Data Monitor Table

-: Not applicable

PID/DATA MONITOR DESCRIPTION [POWER LIFTGATE (PLG) CONTROL MODULE]

PID Unit/Operation Data contents Module control terminal
BCM_ID_RGTR Not Complete/Complete
  • Not Complete: Programming of remote transmitter ID data between body control module (BCM) and liftgate control module is not completed.
  • Complete: Programming of remote transmitter ID data between body control module (BCM) and liftgate control module is completed.
-
CARGO_LAMP_SW Off/On
  • Off: Room light switch is off.
  • On: Room light switch is on.
2AC
CLAW_SW Off/On
  • Off: Claw switch is off.
  • On: Claw switch is on.
2AA
CLOSURE_MOTOR_CLOSE_STAT Off/On
  • Off: Closure motor close is not operating.
  • On: Closure motor close is operating.
-
CLOSURE_MOTOR_CLOSE_VOLT V Displays the voltage during a close operation of the closure motor. 1F
CLOSURE_MOTOR_CUR A Displays the current during closure motor operation. -
CLOSURE_MOTOR_OPEN_STAT Off/On
  • Off: Closure motor open is not operating.
  • On: Closure motor open is operating.
-
CLOSURE_MOTOR_OPEN_VOLT V Displays the voltage during a open operation of the closure motor. 1H
HALF_LATCH_SW Off/On
  • Off: Half latch switch is off.
  • On: Half latch switch is on.
2Y
PLG_MOTOR_CLOSE_STAT_L Off/On
  • Off: Power liftgate drive unit motor (LH) close is not operating.
  • On: Power liftgate drive unit motor (LH) close is operating.
-
PLG_MOTOR_CLOSE_STAT_R Off/On
  • Off: Power liftgate drive unit motor (RH) close is not operating.
  • On: Power liftgate drive unit motor (RH) close is operating.
-
PLG_MOTOR_CLOSE_VOLT_L V Displays the voltage during a close operation of the power liftgate drive unit motor (LH). 1G
PLG_MOTOR_CLOSE_VOLT_R V Displays the voltage during a close operation of the power liftgate drive unit motor (RH). 1C
PLG_MOTOR_CUR_L A Displays the current during power liftgate drive unit motor (LH) operation. -
PLG_MOTOR_CUR_R A Displays the current during power liftgate drive unit motor (RH) operation. -
PLG_MOTOR_OPEN_STAT_L Off/On
  • Off: Power liftgate drive unit motor (LH) open is not operating.
  • On: Power liftgate drive unit motor (LH) open is operating.
-
PLG_MOTOR_OPEN_STAT_R Off/On
  • Off: Power liftgate drive unit motor (RH) open is not operating.
  • On: Power liftgate drive unit motor (RH) open is operating.
-
PLG_MOTOR_OPEN_VOLT_L V Displays the voltage during a open operation of the power liftgate drive unit motor (LH). 1E
PLG_MOTOR_OPEN_VOLT_R V Displays the voltage during a open operation of the power liftgate drive unit motor (RH). 1A
PLG_PULSE_COUNT_L Count Displays pulse count from the power liftgate drive unit (LH) 2H, 2J
PLG_PULSE_COUNT_R Count Displays pulse count from the power liftgate drive unit (RH) 2K, 2M
PLG_SEN_A_L Lo/Hi
  • Low: Hall effect switch 1 (LH) in power liftgate (PLG) drive unit (LH) is on.
  • High: Hall effect switch 1 (LH) in power liftgate (PLG) drive unit (LH) is off.
2H
PLG_SEN_A_R Lo/Hi
  • Low: Hall effect switch 1 (RH) in power liftgate (PLG) drive unit (RH) is on.
  • High: Hall effect switch 1 (RH) in power liftgate (PLG) drive unit (RH) is off.
2K
PLG_SEN_B_L Lo/Hi
  • Low: Hall effect switch 2 (LH) in power liftgate (PLG) drive unit (LH) is on.
  • High: Hall effect switch 2 (LH) in power liftgate (PLG) drive unit (LH) is off.
2J
PLG_SEN_B_R Lo/Hi
  • Low: Hall effect switch 2 (RH) in power liftgate (PLG) drive unit (RH) is on.
  • High: Hall effect switch 2 (RH) in power liftgate (PLG) drive unit (RH) is off.
2M
PLG_STAT Unknown/PLG FullClose/PLG HalfOpen/PLG FullOpen/PLG AutoOpen/PLG AutoClose
  • Unknown: Liftgate operation condition is not determined.
  • PLG FullClose: Liftgate is fully closed.
  • PLG HalfOpen: Liftgate is partly open.
  • PLG FullOpen: Liftgate is fully open.
  • PLG AutoOpen: Liftgate is during auto open operation.
  • PLG AutoClose: Liftgate is during auto close operation.
2A, 2B
RETURN_SW Off/On
  • Off: Motor return switch is off.
  • On: Motor return switch is on.
2AB
TOUCH_SEN_L V Displays voltage at the power liftgate touch sensor (LH) 2N
TOUCH_SEN_R V Displays voltage at the power liftgate touch sensor (RH) 2L
VPWR V Displays voltage at the power supply -
VPWR_IG V Displays power supply voltage of power liftgate control module 2W
VPWR_POWER V Displays power supply voltage of power liftgate control module 1B
VPWR_SEN_SW V Displays power supply voltage of power liftgate control module 2X
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.