2012 Mazda 6 L4-2.5LFACTORY OEM SERVICE PROCEDURE

Alternator: Testing and Inspection





GENERATOR INSPECTION [MZR 2.5]

CAUTION:
1 Do not apply direct battery positive voltage to generator terminal D, otherwise it could cause damage to the internal parts (power transistor) of the generator.

Generator Warning Light

1. Verify that the battery is fully charged.

2. Verify that the drive belt is correct. Testing and Inspection

3. Switch the ignition to ON, verify that the generator warning light illuminates.

- If it does not illuminate, inspect the generator warning light and the wiring harness.

1 If the generator warning light and the wiring harness are normal, inspect the PCM.

4. Verify that the generator warning light goes out after the engine is started.

- If the generator warning light does not go out, perform the DTC inspection, then perform troubleshooting according to the corresponding diagnostic procedure. On-Board Diagnostic Test Engine - DTC Table

Generator

Voltage

1. Verify that the battery is fully charged.

2. Verify that the drive belt is correct. Testing and Inspection

3. Turn off all electrical loads.

4. Start the engine.

5. Verify that the generator rotates smoothly without any noise while the engine is running.

- If there is any noise, find the cause and repair or replace the generator.

6. Measure the voltage at each terminal using a tester.

Factory service manual diagram





- If it is not as specified, find the cause and repair or replace the applicable part.

Generator standard voltage [IG-ON]
- Terminal B: B+
- Terminal P: Approx. 1 V or less
- Terminal D: Approx. 0 V

Generator standard voltage [Idle, 20 °C {68 °F}]
- Terminal B: 13-15 V
- Terminal P: Approx. 3-8 V
- Terminal D: Turn the electrical loads (headlights, blower motor, rear window defroster, brake lights, etc.) on and verify that the voltage reading increases.

Current

NOTE:
1 Since the charging current decreases rapidly after starting the engine, carry out the following procedure quickly, and read the maximum current value.

1. Verify that the battery is fully charged.

2. Verify that the drive belt is correct. Testing and Inspection

3. Disconnect the negative battery cable.

4. Connect a tester, which can read 120 A or more, between generator terminal B and the wiring harness.

5. Connect the negative battery cable.

6. Turn off all electrical loads.

7. Start the engine.

8. Increase engine speed to 2,500 rpm.

NOTE:
1 When the electrical load on the vehicle is low, the specified current cannot be verified although the generator is normal. In this case, increase the electrical load (Leave the headlights turned on for a while, then discharge the battery, or use a similar method.) and recheck.
2 When the generator itself or the ambient temperature are too high, the specified current also cannot be verified. In this case, cool down the generator and recheck.

9. Turn the electrical loads (headlights, blower motor, rear window defroster, brake lights, etc.) on and verify that the current reading increases more than the minimum value indicated below.
1 If it is not as specified, go to the PCM and generator shearing inspection.

Generator generated current minimum value
- 70% of the nominal output current (nominal output current: 100 A)
- [Ambient temp. 20 °C {68 °F}, voltage 13.0-15.0 V, both engine and generator are hot]

PCM and generator shearing inspection

1. Connect the M-MDS to the DLC-2.

Factory service manual diagram





2. Inspect as follows:

Factory service manual diagram




Factory service manual diagram




*1
Headlights, blower motor, rear window defroster, brake lights, etc.
*2
If the generator field coil duty value does not change when electrical loads (such as headlights, blower motor, rear window defroster, brake lights) are on or off, inspection with discharged battery is needed.

Generator Inner Parts

Rotor

1. Measure the resistance between the slip rings using a tester.

Factory service manual diagram





- If not within specification, replace the rotor.

Generator rotor resistance (between slip rings) [20 °C {68 °F}]
- 2.0-2.3 ohms

2. Verify that there is no continuity between the slip ring and core using a tester.

Factory service manual diagram





- If there is continuity, replace the rotor.

3. Inspect the slip ring surface condition.

- If the slip ring surface is rough, use a lathe or fine sandpaper to make it smooth.

Stator coil

1. Verify that the continuity is as indicated in the table.

Factory service manual diagram





Factory service manual diagram





- If there is any malfunction, replace the stator.

2. Verify that there is no continuity between the stator coil leads and core using a tester.

Factory service manual diagram





- If there is continuity, replace the stator coil.

Brush

1. Inspect brushes for wear.

Factory service manual diagram





- If any brush is worn almost to or beyond the limit, replace all of the brushes.

Generator brush length
- Standard: 22.5 mm {0.886 in}
- Minimum: 5.0 mm {0.20 in}

Brush spring

1. Measure the force of the brush spring using a spring pressure gauge.

2. Read the spring pressure gauge at the brush tip projection of 2 mm {0.08 in}.

Factory service manual diagram





- Replace the brush spring if necessary.

Generator brush spring force
- Standard: 4.1-5.3 N {0.42-0.54 kgf, 1.0-1.1 lbf}
- Minimum: 1.7 N {0.17 kgf, 0.38 lbf}

Rectifier (Using an analog circuit tester)

1. Inspect for continuity of the diodes using an analog circuit tester.

Factory service manual diagram





- If not as specified, replace the rectifier.

Specification

Factory service manual diagram




Rectifier (Using a digital circuit tester)

1. Inspect for continuity of the diodes using a digital circuit tester.

- If not as specified, replace the rectifier.

Specification

Factory service manual diagram




Bearing

1. Inspect for abnormal noise, looseness, and sticking.

Factory service manual diagram





- Replace the bearing if necessary.

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.