2007 Mazda Mazdaspeed6 L4-2.3L TurboFACTORY OEM SERVICE PROCEDURE

Knock Sensor: Testing and Inspection

KNOCK SENSOR (KS) INSPECTION[L3 WITH TC]

NOTE: Perform the following test only when directed.

Resistance Inspection
1. Turn the ignition switch to the LOCK position.
2. Disconnect the KS connector.
3. Measure the resistance between the KS terminals A and B using a tester.
- If not as specified, replace the KS.
- If the KS is normal, but PID value is out of specification, perform the "Circuit Open/Short Inspection".

Specification: Approx. 4.87 megohms

Circuit Open/short Inspection

Factory service manual diagram



1. Disconnect the PCM connector.
2. Inspect the following wiring harnesses or an open or short circuit. (Continuity check)

Open circuit
- If there is no continuity, there is an open circuit. Repair or replace the wiring harness.
- KS terminal A and PCM terminal 25
- KS terminal B and PCM terminal 2P

Short circuit
- If there is continuity, there is a short circuit. Repair or replace the wiring harness.
- KS terminal A and power supply
- KS terminal A and body ground
- KS terminal B and power supply
- KS terminal B and body ground
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.