2007 Mazda Mazdaspeed3 L4-2.3L TurboFACTORY OEM SERVICE PROCEDURE

Using SST (M-MDS)

Using the M-MDS

NOTE
- PIDs for the following parts are not available on this model. Perform the specific inspections for the following parts:
- CMP sensor (See CAMSHAFT POSITION (CMP) SENSOR INSPECTION[L3 WITH TC].) Component Tests and General Diagnostics
- Main relay

Factory service manual diagram



1. Connect the M-MDS to the DLC-2.
2. Turn the ignition switch to the ON position.
3. Measure the PID value.
- If PID value is not within the specification, follow the instructions in the "Inspection item" column.

NOTE
- The PID/DATA MONITOR function monitors the calculated value of the input/output signals in the PCM. Therefore, an output device malfunction is not directly indicated as a malfunction of the monitored value for the output device. If a monitored value of an output device is out of specification, inspect the monitored value of the input device related to the output control.
- For input/output signals except those of the monitoring items, use a voltmeter to measure the PCM terminal voltage.
- The simulation items that are used in the ENGINE CONTROL SYSTEM OPERATION INSPECTION are as follows.
- ACCS, ALTF, ARPMDES, FAN_DUTY, EVAPCP, FP, FUELPW1, GENVDSD, HTR11, HTR12, IMRC, INJ_1, INJ_2, INJ_3, INJ_4, SEGRP, test, VT DUTY1 Wt, WGC
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.