2007 Mazda CX-9 V6-3.5LFACTORY OEM SERVICE PROCEDURE

Camshaft Position Sensor: Testing and Inspection

CAMSHAFT POSITION (CMP) SENSOR INSPECTION [MZI-3.5]

NOTE: Before performing the following inspection, make sure to follow the procedure as indicated in the troubleshooting flowchart.

Visual Inspection
1. Remove the CMP sensor.
2. Verify that there are no metal shavings on the CMP sensor.
3. Install the CMP sensor.

Resistance Inspection
1. Remove the CMP sensor connector.
2. Measure the resistance between the CMP sensor terminals.
- If not within the specification, replace the CMP sensor.
- If the monitor item status/specification (reference) is not within the specification, even though the resistance is within the specification, perform the "Circuit Open/Short Inspection".

CMP sensor resistance: 800-1320 ohms

Circuit Open/Short Inspection

Factory service manual diagram



1. Disconnect the PCM connector.
2. Inspect the following harness for open or short circuit. (Continuity check)

Open circuit
- CMP sensor (RH) terminal A and PCM terminal 2X
- CMP sensor (RH) terminal B and PCM terminal 2C
- CMP sensor (LH) terminal A and PCM terminal 2AB
- CMP sensor (LH) terminal B and PCM terminal 2C

Short circuit
- CMP sensor (RH) terminal A and power supply
- CMP sensor (RH) terminal A and body ground
- CMP sensor (RH) terminal B and power supply
- CMP sensor (LH) terminal A and power supply
- CMP sensor (LH) terminal A and body ground
- CMP sensor (LH) terminal B and power supply
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.