Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
Wastegate Control System Operation Inspection
If simulation function of M-MDS is used:Β
- Start the engine and run it is idling.
- Disconnect the hose between the wastegate control solenoid valve and the intake pipe.
- Put a finger to the wastegate control solenoid valve and verify that there is no pressure applied.
- If there is pressure, inspect the following:
- Wiring harness and connectors (Wastegate control solenoid valve-PCM terminal 4H)
- Wastegate control solenoid valve (Stuck open)
- If there is pressure, inspect the following:
- Warm up the engine to normal operating temperature.
- Connect the M-MDS to the DLC-2 and verify that DTC P0245 or P0246 are shown. Perform the DTC inspection.
(See DTC P0245 ).
(See DTC P0246 ).
- Select the VGT PID.
- Increase the duty value of the wastegate control solenoid valve and inspect if the operation sound of the solenoid valve is heard.
- If the operation sound is heard, inspect for loose or damaged vacuum hoses. (Wastegate actuator - wastegate control solenoid valve - intake hose)
- If the operation sound is not heard, perform the wastegate control solenoid valve inspection. (See WASTEGATE CONTROL SOLENOID VALVE INSPECTION ).
- Warm up the engine to normal operating temperature.
- Monitor the VGT and APP PIDs using the M-MDS.
- Run the engine with the APP PID above 30%Β
and verify that the VGT PID value increases from 0%.Β
- If the VGT PID is 0%Β , inspect the APP PID.
If simulation function of M-MDS is not used:Β
- Start the engine and run it is idling.
- Disconnect the hose between the wastegate control solenoid valve and the intake pipe.
- Put a finger to the wastegate control solenoid valve and verify that there is no pressure applied.
- If there is pressure, inspect the following:
- Wiring harness and connectors (Wastegate control solenoid valve - PCM terminal 4H)
- Wastegate control solenoid valve (Stuck open)
- If there is pressure, inspect the following:
- Warm up the engine to normal operating temperature.
- Connect the M-MDS to the DLC-2 and verify that the DTC P0245 or P0246 are shown. Perform the DTC inspection.
(See DTC P0245 ).
(See DTC P0246 ).
- Warm up the engine to normal operating temperature.
- Monitor the VGT and APP PIDs using the M-MDS.
- The hose between the wastegate control solenoid valve and intake pipe is disconnected.
- Run the engine with the APP PID above 30%Β
and verify that the VGT PID value increases from 0% and there is pressure applied.
- If the VGT PID is 0%Β , inspect the TP_REL PID.
- If there is no pressure applied, inspect for the following:
- Wastegate control solenoid valve (Stuck closed)
- Hose connection (Intake hose (turbocharger compressor downstream side) - wastegate actuator - intake hose (turbocharger compressor upstream side)
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.
Rather have a pro handle this?
A certified mobile mechanic comes to your home or office. They bring the tools, you stay comfortable. No tow truck, no waiting room, no surprises.
No obligation. See pricing before you book.