2007 Mazda 6 L4-2.3LFACTORY OEM SERVICE PROCEDURE

[AW6A-EL]

TCM INSPECTION [AW6A-EL]

TR Switch Operating Inspection
1. Verify that the starter operates only when the ignition switch is turned to the START position with the selector lever in P or N position.
^ If there is any malfunction, neutral position learning.
2. Verify that the back-up lights illuminate when shifted to R position with the ignition switch at the ON position.
^ If there is any malfunction, neutral position learning.

Factory service manual diagram




3. Verify that the positions of the selector lever and the indicator light correspond.
^ If there is any malfunction, perform the neutral position learning.
4. Verify that the TR PID is normal.
^ If there is any malfunction, perform the neutral position learning.

Control Module Inspection
1. Remove the air cleaner component.
2. Measure the voltage at each TCM short cord connector wiring harness-side) terminal and refer to the terminal voltage table.
^ If the voltage is not as specified in the Terminal Voltage Table (Reference), inspect the parts under "Inspection item (s)".

Warning: Be careful not to damage the connector waterproofing when measuring the TCM terminal voltage. If damaged, the waterproofing efficiency could be negatively affected.

Note: Use the ground of terminal J of the TCM short cord connector wiring harness-side) when measuring terminal voltage, as an error may occur when connecting the negative circuit tester to ground.

Terminal Voltage Table (Reference) (Part 1):

Factory service manual diagram



Terminal Voltage Table (Reference) (Part 2):

Factory service manual diagram



Terminal Voltage Table (Reference) (Part 3):

Factory service manual diagram




3. Remove the TCM.
4. Verify that continuity or resistance at terminal is as indicated in the terminal continuity/resistance table.
^ If there is any malfunction, inspect the parts under "Inspection item (s)".
- If the system does not work properly even though the parts or related wiring harnesses do not have any malfunction, replace the TCM.

Terminal Continuity/Resistance Table (Reference) (Part 1):

Factory service manual diagram



Terminal Continuity/Resistance Table (Reference) (Part 2):

Factory service manual diagram



Terminal Continuity/Resistance Table (Reference) (Part 3):

Factory service manual diagram



Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.