2007 Mazda 3 i, 2.0 F, AutomaticFACTORY OEM SERVICE PROCEDURE

Continuity Inspection

  1. Remove the neutral switch. (See NEUTRAL SWITCH REMOVAL/INSTALLATION .)
  2. Verify that the continuity between neutral switch terminals A and B is as indicated in the table.
    • If it can be verified, perform the "CIRCUIT OPEN/SHORT INSPECTIONΒ ".
    • If it cannot be verified, replace the neutral switch.
      CONTINUITY REFERENCE

      Measured condition Continuity
      Rod pushed Continuity detected
      Except above No continuity
      Fig 1: Identifying Neutral Switch Connector Terminals
      G04955221Courtesy of MAZDA MOTORS CORP.