2005 Mazda 3 i, AutomaticFACTORY OEM SERVICE PROCEDURE

Generator Inspection: Generator: Current

NOTE:
  • Since the charging current decreases rapidly after starting the engine, carry out the following procedure quickly, and read the maximum current value.
  1. Verify that the battery is fully charged.
  2. Verify that the drive belt deflection/tension is correct. (See DRIVE BELT INSPECTION .)
  3. Disconnect the negative battery cable.
  4. Connect a tester capable of reading 120 A or above  between generator terminal B and the wiring harness.
  5. Connect the negative battery cable.
  6. Turn off all electrical loads.
  7. Start the engine.
  8. Increase engine speed to 2,500 rpm. 
    NOTE:
    • When the electrical load of the vehicle is low, specified current will not be verified although the generator is normal. In this case, increase the electrical load (turn on the headlight and leave it for a while, then discharge the battery, etc.) and recheck.
    • When the generator itself or the ambient temperature are too high, specified current will also not be verified. In this case, cool down the generator and recheck.
  9. Turn the following electrical loads on and verify that the current reading increases more than the minimum value indicated below.
    • Headlights (high-beam)
    • Blower motor (high)
    • Rear window defroster
    • Stop lamp

Minimum current value 

  1. 70 % of the nominal output current (nominal output current: 90 A) 
    1. [ambient temp. 20°C {68 °F}, voltage 13.0-15.0 V, both engine and generator are cold 
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.