Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
2004 Mazda 3 L4-2.3LFACTORY OEM SERVICE PROCEDURE
Catalytic Converter: Service and Repair
THREE WAY CATALYTIC CONVERTER (TWC) REPLACEMENT [EXCEPT FOR CALIFORNIA EMISSION REGULATION APPLICABLE MODEL]
Note: The TWC is integrated with the presilencer and main silencer. Therefore, when replacing the TWC, cut between the TWC and presilencer.

Cut Location
1. Remove the rear tunnel member.
2. Remove the front tunnel member.
Caution: Be careful not to deform the pipe when cutting. If the pipe is deformed, the new pipe may not be installed correctly.

3. Cut the pipe between the TWC and presilencer using the following procedure. (Cut location A)
1 Measure the length from the hanger inner edge.
2 Cut the pipe at the specified location.
4. Remove the nut and TWC.
5. Remove burrs from the cut surface on the presilencer side using a round file.
6. Install the new TWC to the presilencer using the following procedure. (Cut location A)

1 Measure the indicated length from the cut surface of the presilencer and mark.
2 Apply heat-resistant sealant to the marked position along the complete perimeter.
Note: The TWC installation nut should remain untightened.
3 Replace the gasket with a new one and install the new TWC to the HU-TWC.
Note: The U-shaped bolt can be inserted to the pipe on either side.

4 Insert the U-shaped bolt.

5 Insert the TWC to the presilencer, and align the cut surface of the pipe with the marking.
7. Tighten the TWC installation nut.
8. Tighten the U-shaped bolt between the presilencer and the new TWC using the following procedure. (Cut location A)
Note: The TWC has a marked line at the specified position where the U-shaped bolt is to be set.

1 Set the U-shaped bolt in the specified position.

2 Set the U-shaped bolt so that the clearance between the bolt and surrounding parts is as indicated in the figure.
A: Clearance between the U-shaped bolt end and the vehicle side insulator 10 mm (0.40 inch) or longer
B: Clearance between the U-shaped bolt and the tunnel member 20 mm (0.79 inch) or longer
Caution:
^ Do not loosen U-shaped bolt after tightening. If it is loosened, the bolt cannot be tightened at the specified torque with the specified protrusion.
^ Tighten the U-shaped bolt in three or four steps, left and right equally, to prevent clamp deformation.
3 Tighten the U-shaped bolt.
Protrusion of U-shaped bolt after tightening 17 - 19 mm (0.67 - 0.74 inch)
Note: The TWC is integrated with the presilencer and main silencer. Therefore, when replacing the TWC, cut between the TWC and presilencer.
Cut Location
1. Remove the rear tunnel member.
2. Remove the front tunnel member.
Caution: Be careful not to deform the pipe when cutting. If the pipe is deformed, the new pipe may not be installed correctly.
3. Cut the pipe between the TWC and presilencer using the following procedure. (Cut location A)
1 Measure the length from the hanger inner edge.
2 Cut the pipe at the specified location.
4. Remove the nut and TWC.
5. Remove burrs from the cut surface on the presilencer side using a round file.
6. Install the new TWC to the presilencer using the following procedure. (Cut location A)
1 Measure the indicated length from the cut surface of the presilencer and mark.
2 Apply heat-resistant sealant to the marked position along the complete perimeter.
Note: The TWC installation nut should remain untightened.
3 Replace the gasket with a new one and install the new TWC to the HU-TWC.
Note: The U-shaped bolt can be inserted to the pipe on either side.
4 Insert the U-shaped bolt.
5 Insert the TWC to the presilencer, and align the cut surface of the pipe with the marking.
7. Tighten the TWC installation nut.
8. Tighten the U-shaped bolt between the presilencer and the new TWC using the following procedure. (Cut location A)
Note: The TWC has a marked line at the specified position where the U-shaped bolt is to be set.
1 Set the U-shaped bolt in the specified position.
2 Set the U-shaped bolt so that the clearance between the bolt and surrounding parts is as indicated in the figure.
A: Clearance between the U-shaped bolt end and the vehicle side insulator 10 mm (0.40 inch) or longer
B: Clearance between the U-shaped bolt and the tunnel member 20 mm (0.79 inch) or longer
Caution:
^ Do not loosen U-shaped bolt after tightening. If it is loosened, the bolt cannot be tightened at the specified torque with the specified protrusion.
^ Tighten the U-shaped bolt in three or four steps, left and right equally, to prevent clamp deformation.
3 Tighten the U-shaped bolt.
Protrusion of U-shaped bolt after tightening 17 - 19 mm (0.67 - 0.74 inch)
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.