2004 Mazda 3 L4-2.3LFACTORY OEM SERVICE PROCEDURE

Heating and Air Conditioning: Service and Repair

REFRIGERANT CHARGING

CAUTION: Do not exceed the specification when charging the system with refrigerant. Doing a, will decrease the efficiency of the air conditioner or damage the refrigeration cycle parts.

Charging Recycled R-134a Refrigerant
1. Connect an R-134a recovery/recycling/recharging device to the vehicle and follow the device manufacturer's instructions.

Charging Preparation
1. Install the manifold gauge set.
2. Connect the tap pin side of the charging hose to the air purge valve of the manifold gauge.
3. Connect the vacuum pump hose to the center joint of the manifold gauge.
4. Connect the vacuum pump hose to the vacuum pump.
5. Connect the charging hose to the refrigerant tank.

Factory service manual diagram



6. Place the refrigerant tank on the scale.

Regular amount of refrigerant (approx. quantity)
475-525 g (16.8-18.5 oz)

Evacuation
1. Open all the valves of the manifold gauge.

CAUTION: Close the manifold gauge valve immediately after stopping the vacuum pump. If the valve is left open, the vacuum pump oil will flow back into the refrigeration cycle and cause a decrease in the efficiency of the air conditioner.

Factory service manual diagram



2. Start the vacuum pump and let it operate for 15 min.

Factory service manual diagram



3. Verify that high- and low-pressure side readings of the manifold gauge are at -101 kPa {-760 mmHg, -29.9 inHg}. Close each valve of the manifold gauge.

Airtightness Check
1. Stop the vacuum pump and wait for 5 min.
2. Check the high- and low-pressure side readings of the manifold gauge.
- If the reading has changed, inspect for leakage and go to Evacuation.
- If the reading has not changed, go to Charging New R-134a Refrigerant.

Charging New R-134a Refrigerant
1. Open the valve of the refrigerant tank.
2. Weigh the refrigerant tank to charge the suitable amount of refrigerant.

WARNING:
- If the refrigerant system is charged with a large amount of refrigerant when inspecting for gas leakage, and if any leakage should occur, the refrigerant will be released into the atmosphere. In order to prevent the accidental release of refrigerant which can destroy the ozone layer In the stratosphere, follow the proper procedures and charge with only a small amount of refrigerant when inspecting for gas leakage.
- If charging the system with refrigerant using service cans, running the engine with the high- pressure side valve open is dangerous. Pressure within the service cans will increase and the cans could explode, scattering metal fragments and liquid refrigerant that can seriously injure you. Therefore, do not open the high-pressure side valve while the engine is running.


CAUTION: Always being charging of refrigerant from the high-pressure side. If changing is begun from the low-pressure side, the vanes of the A/C compressor will not be released and abnormal noise may result.

Factory service manual diagram



3. Open the high-pressure side valve of the manifold gauge.

Factory service manual diagram



4. When the low-pressure side reading increases to 0.098 MPa (1.0 kgf/sq.cm, 14 psi), close the high-pressure side valve of the manifold gauge.
5. Inspect for leakage from the cooler pipe/hose connections using a gas leak tester.
- If there is no leakage, go to Step 7.
- If leakage is found at a loose joint, tighten the joint, then go to the next step.

6. Inspect for leakage again.
- If there is no leakage after tightening the joint, go to the next step.
- If there is still a leakage at the same joint, discharge the refrigerant and then repair the joint. Repeat the charging procedure from evacuation.

WARNING: If charging the system with refrigerant using service cans, running the engine with the high-pressure side valve open is dangerous. Pressure within the service cans will increase and the cans could explode, scattering metal fragments and liquid refrigerant that can seriously injure you. Therefore, do not open the high-pressure side valve while the engine is running.

Factory service manual diagram



7. Open the high-pressure side valve of the manifold gauge and charge with refrigerant until the weight of refrigerant tank has decreased 238-263 g {8.40-9.28 oz} from the amount in Step 2.

Factory service manual diagram



8. Close the low-pressure side valve of the manifold gauge.

WARNING: If charging the system with refrigerant using service cans, running the engine with the high-pressure side valve open is dangerous. Pressure within the service cans will increase and the cans could explode, scattering metal fragments and liquid refrigerant that can seriously injure you. Therefore, do not open the high-pressure side valve while the engine is running.

9. Start the engine and actuate the A/C compressor.

Factory service manual diagram



10. Open the low-pressure side valve of the manifold gauge and charge with refrigerant until the weight of the refrigerant tank has decreased regular amount from the amount in Step 2.
11. Close the low-pressure side valve of the manifold gauge and the valve of the refrigerant tank.
12. Stop the engine and A/C compressor.

Leak Test
1. Inspect for leakage using the a gas leak tester.
- If there is no leakage, go to Step 3.
- If leakage is found at a loose joint, tighten the joint, then go to the next step.
2. Inspect for leakage again.
- If there is no leakage after tightening the joint, go to the next step.
- If there is still leakage at the same joint, discharge the refrigerant and then repair the joint. Repeat the charging procedure from evacuation.
3. Disconnect the manifold gauge from the charging valves.

Factory service manual diagram



4. Install the caps to the charging valves.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.