2000 Mazda MPV ES V6-2.5L DOHCFACTORY OEM SERVICE PROCEDURE

Component Inspection

NOTE: Perform the following test only when directed.

Continuity Inspection
1. Disconnect the negative battery cable.

Factory service manual diagram



2. Remove the main relay.

Factory service manual diagram



3. Inspect for continuity between main relay terminals using an ohmmeter.
- If not as specified, replace the main relay.
- If the main relay is okay, but PCM terminal 71 or 97 voltage are Out of specification, perform the "Circuit Open/Short Inspection".

Circuit Open/Short Inspection
1. Remove the PCM.

Factory service manual diagram



2. Connect the SST (104 Pin Breakout Box) with the PCM disconnected.
3. Tighten the connector attaching bolt.

Tightening torque
7.9 - 10.7 N.m {80 - 110 kgf.cm, 69.5 - 95.4 in.lbf}

4. Inspect the following wiring harness for open (Continuity check).

Open circuit

Factory service manual diagram



- If there is no continuity, the circuit is open. Repair or replace the harness.
- Main relay terminal A (harness-side) and battery positive terminal (IG ON)
- Main relay terminal C (harness-side) and battery positive terminal.
- Main relay terminal B (harness-side) and battery negative terminal.

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.