1995 Mazda RX-7 AutomaticFACTORY OEM SERVICE PROCEDURE

2-Way Check Valve

Remove check valve. Connect a vacuum pump to outlet end of check valve (see arrow on valve). Air should flow with about 1.7 in. Hg vacuum applied. Connect vacuum pump to other end of check valve. Air should also flow with about 1.00-1.46 in. Hg vacuum applied. Replace valve as necessary.

Fig 1: Identifying Evaporative Control System Components
G95G33163Courtesy of MAZDA MOTORS CORP.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.