1994 Mazda 929FACTORY OEM SERVICE PROCEDURE

Continuity Test

  1. Check METER fuse and ABS warning light bulb. Check wiring harness between ABS warning light and ABS control unit, and between ABS warning light and hydraulic unit. Repair or replace as necessary. Disconnect hydraulic unit connector.
  2. Connect positive lead of DVOM to terminal "G" (Gray wire) and negative lead to Yellow/Red wire terminal of hydraulic unit connector. See Fig 1 .
  3. Ensure continuity is present between terminals. Reverse DVOM leads. Continuity should not be present with leads reversed. If ABS diode does not test as described, replace hydraulic unit.
Fig 1: Hydraulic Unit Harness Connector & Instrument Cluster Connector Terminals
G93F00856Courtesy of MAZDA MOTORS CORP.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.