1982 Mazda RX7 2RTR-1146cc 70FACTORY OEM SERVICE PROCEDURE

Engine Control Module: Testing and Inspection

Fig. 22 Engine control unit terminal identification:

Factory service manual diagram




1. Start engine and allow to reach normal operating temperature.
2. Check control unit fuse. If fuse has blown, replace fuse.
3. Operate engine at idle and using a suitable voltmeter, ensure current flows to terminals (B), (J), (R) and (0), Fig 22.
4. With engine idling, check voltage at terminal (A). Voltage should be 3-8 volts.
5. On vehicles equipped with automatic transmission, position shift lever in "Park" position, then disconnect electrical connector from carburetor throttle sensor and connect another throttle sensor to connector.


Fig. 23 Engine control unit testing procedure chart:

Factory service manual diagram




6. Connect voltmeter negative lead to (P) terminal, then with engine operating as shown in chart Fig. 23, connect positive lead to terminals indicated and check for voltage specified. If voltage is not as specified, check circuit of terminal being tested. If circuit is normal, replace engine control unit

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.