1982 Mazda RX7 2RTR-1146cc 70FACTORY OEM SERVICE PROCEDURE

Coolant Temperature Sensor/Switch (For Computer): Testing and Inspection


1. Remove No. 1 water temperature switch from water pump and No. 2 switch from lower radiator tank.
2. Place switch No. 1 in a container of water, then heat water gradually. Using a thermometer and ohmmeter, determine at what temperature continuity between terminals in coupler ceases. Continuity should cease between 146° and 170° F. If not as specified, replace water temperature switch.
3. Place switch No. 2 in a container of water, then heat water gradually. Using a thermometer and ohmmeter, determine at what temperature continuity exists between terminals. There should be continuity at 65° to 79° F and no continuity at all other temperatures. If not as specified, replace water temperature switch.



Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.