1981 Mazda B2000 BaseFACTORY OEM SERVICE PROCEDURE

THERMO Switch (626 Only)

Drain radiator. Remove electrical connector from thermo switch and remove thermo switch from radiator lower tank. Attach leads to switch terminals and place switch in container of water with thermometer. Connect ohmmeter to switch leads. Gradually heat water and note temperature at which no continuity exists. If temperature is not as specified in Thermo Valve/Switch Specifications table, replace thermo switch.

Thermo Valve/Switch Specifications (Temperature)

Application No. 1 Valve Β°F(Β°C) No. 2 Valve Β°F(Β°C)
GLC 66(19) 132(55)
GLC Wagon 70(21) 138(59)
626 (1) 129(54)
B2000 Β  122(50)
(1) Thermo switch - No continuity between 59-66Β° F (15-19Β°C).
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.

Rather have a pro handle this?

A certified mobile mechanic comes to your home or office. They bring the tools, you stay comfortable. No tow truck, no waiting room, no surprises.

Comes to youSame-day available12-month warranty
Get a Free Quote

No obligation. See pricing before you book.