1995 Lincoln Mark VIII BaseFACTORY OEM SERVICE PROCEDURE

Master Switch

CAUTION: The following test are performed with lockout switch closed (non-lockout position)
  1. Remove master switch from vehicle. Test using self-powered test light or ohmmeter. Replace window control switch if continuity is not as specified in testing. With switch in neutral position, continuity should be present between terminals "A" and "B", "D" and "E", "I" and "L", and terminals "K" and "M". See Fig 1 .
  2. Right Front Circuit With master switch in right front UP position, continuity should be present between terminals "A" and "B", "D" and "E", "I" and "L", and terminals "J"and "K". With switch in right front DOWN position, continuity should be present between terminals "A" and "B", "D" and "E", "I" and "", and terminals "K" and "M".
  3. Left Front Circuit With master switch in left front UP position, continuity should be present between terminals "A" and "B", "C" and "D", "I" and "L", and terminals "K" and "M". With switch in left front DOWN position, continuity should be present between terminals "B" and "C", "D" and "E", "I" and "L", and terminals "K" and "M".
Fig 1: Master Switch Test Terminals (Mark VIII)
G95J14968Courtesy of FORD MOTOR CO.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.