Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
2024 Lexus RZ 450e PremiumFACTORY OEM SERVICE PROCEDURE
Motor Generator Control System
MOTOR GENERATOR CONTROL SYSTEM DIAGNOSTIC TROUBLE CODE (DTC) IDENTIFICATION [01/2023 - 11/2023]
| DTC Code | Description |
|---|---|
| P062F-46 | Generator Control Module(EEPROM Learning Value) Calibration / Parameter Memory Failure |
| P06B0-1C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
| P06B3-1C | Drive Motor "B" Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
| P06B3-1F | Drive Motor "B" Control Module Position Sensor REF Power Source Circuit Intermittent |
| P06D6-1C | Generator Control Module Offset Power Circuit Voltage Out of Range |
| P0A00-11 | Motor Electronics Coolant Temperature Sensor Circuit Short to Ground |
| P0A00-15 | Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open |
| P0A00-1C | Motor Electronics Coolant Temperature Sensor Circuit Voltage Out of Range |
| P0A1B-00 | Drive Motor "A" Control Module Performance |
| P0A1B-04 | Drive Motor "A" Control Module System Internal Failure |
| P0A1B-1F | Generator Control Module Circuit Intermittent |
| P0A1B-29 | Drive Motor "A" Control Module Signal Invalid |
| P0A1B-47 | Drive Motor "A" Control Module Watchdog / Safety MC Failure |
| P0A1C-00 | Drive Motor "B" Control Module Performance |
| P0A1C-04 | Drive Motor "B" Control Module System Internal Failure |
| P0A1C-1F | Drive Motor "B" Control Module Circuit Intermittent |
| P0A1C-29 | Drive Motor "B" Control Module Signal Invalid |
| P0A1C-47 | Drive Motor "B" Control Module Watchdog / Safety MCU Failure |
| P0A2A-11 | Drive Motor "A" Temperature Sensor Circuit Short to Ground |
| P0A2A-15 | Drive Motor "A" Temperature Sensor Circuit Short to Auxiliary Battery or Open |
| P0A2A-1C | Drive Motor "A" Temperature Sensor Voltage Out of Range |
| P0A2A-1F | Drive Motor "A" Temperature Sensor Circuit Intermittent |
| P0A30-11 | Drive Motor "B" Temperature Sensor Circuit Short to Ground |
| P0A30-15 | Drive Motor "B" Temperature Sensor Circuit Short to Battery or Open |
| P0A30-1C | Drive Motor "B" Temperature Sensor Circuit Voltage Out of Range |
| P0A30-1F | Drive Motor "B" Temperature Sensor Circuit Intermittent |
| P0A3F-16 | Drive Motor "A" Position Sensor Circuit Voltage Below Threshold |
| P0A3F-1F | Drive Motor "A" Position Sensor Circuit Intermittent |
| P0A3F-21 | Drive Motor "A" Position Sensor Signal Amplitude < Minimum |
| P0A3F-22 | Drive Motor "A" Position Sensor Signal Amplitude > Maximum |
| P0A3F-2B | Drive Motor "A" Position Sensor Signal Cross Coupled |
| P0A45-16 | Drive Motor "B" Position Sensor Circuit Voltage Below Threshold |
| P0A45-1F | Drive Motor "B" Position Sensor Circuit Intermittent |
| P0A45-21 | Drive Motor "B" Position Sensor Signal Amplitude < Minimum |
| P0A45-22 | Drive Motor "B" Position Sensor Signal Amplitude > Maximum |
| P0A45-2B | Drive Motor "B" Position Sensor Signal Cross Coupled |
| P0A5D-12 | Drive Motor "A" Phase U Current (High Resolution) Circuit Short to Battery |
| P0A5D-14 | Drive Motor "A" Phase U Current (High Resolution) Circuit Short to Ground or Open |
| P0A5D-1C | Drive Motor "A" Phase U Current (High Resolution) Circuit Voltage Out of Range |
| P0A5D-1F | Drive Motor "A" Phase U Current (High Resolution) Circuit Intermittent |
| P0A63-12 | Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Battery |
| P0A63-14 | Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Ground or Open |
| P0A63-1C | Drive Motor "A" Phase W Current(High Resolution) Circuit Voltage Out of Range |
| P0A63-1F | Drive Motor "A" Phase W Current(High Resolution) Circuit Intermittent |
| P0A66-12 | Drive Motor "B" Phase U Current (High Resolution) Circuit Short to Battery |
| P0A66-14 | Drive Motor "B" Phase U Current (High Resolution) Circuit Short to Ground or Open |
| P0A66-1C | Drive Motor "B" Phase U Current (High Resolution) Circuit Voltage Out of Range |
| P0A66-1F | Drive Motor "B" Phase U Current (High Resolution) Circuit Intermittent |
| P0A6C-12 | Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Battery |
| P0A6C-14 | Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Ground or Open |
| P0A6C-1C | Drive Motor "B" Phase W Current(High Resolution) Circuit Voltage Out of Range |
| P0A6C-1F | Drive Motor "B" Phase W Current(High Resolution) Circuit Intermittent |
| P0A78-72 | Drive Motor "A" Inverter Actuator Stuck Open |
| P0A78-73 | Drive Motor "A" Inverter Actuator Stuck Closed |
| P0A78-9E | Drive Motor "A" Inverter Stuck On |
| P0A79-72 | Drive Motor "B" Inverter Actuator Stuck Open |
| P0A79-73 | Drive Motor "B" Inverter Actuator Stuck Closed |
| P0A79-9E | Drive Motor "B" Inverter Stuck On |
| P0A90-00 | Drive Motor "A" Performance |
| P0A91-00 | Drive Motor "B" Performance |
| P0AED-11 | Drive Motor Inverter Temperature Sensor "A" Circuit Short to Ground |
| P0AED-15 | Drive Motor Inverter Temperature Sensor "A" Circuit Short to Battery or Open |
| P0AED-1C | Drive Motor Inverter Temperature Sensor "A" Circuit Voltage Out of Range |
| P0AF2-11 | Drive Motor Inverter Temperature Sensor "B" Circuit Short to Ground |
| P0AF2-15 | Drive Motor Inverter Temperature Sensor "B" Circuit Short to Battery or Open |
| P0AF2-1C | Drive Motor Inverter Temperature Sensor "B" Circuit Voltage Out of Range |
| P0BE5-12 | Drive Motor "A" Phase U Current Sensor Circuit Short to Battery |
| P0BE5-14 | Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open |
| P0BE5-28 | Drive Motor A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure" |
| P0BE9-12 | Drive Motor "A" Phase V Current Sensor Circuit Short to Battery |
| P0BE9-14 | Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open |
| P0BE9-28 | Drive Motor A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure" |
| P0BED-12 | Drive Motor "A" Phase W Current Sensor Circuit Short to Battery |
| P0BED-14 | Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open |
| P0BED-28 | Drive Motor A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure" |
| P0BF1-12 | Drive Motor "B" Phase U Current Sensor Circuit Short to Battery |
| P0BF1-14 | Drive Motor "B" Phase U Current Sensor Circuit Short to Ground or Open |
| P0BF1-28 | Drive Motor "B" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
| P0BF5-12 | Drive Motor "B" Phase V Current Sensor Circuit Short to Battery |
| P0BF5-14 | Drive Motor "B" Phase V Current Sensor Circuit Short to Ground or Open |
| P0BF5-28 | Drive Motor "B" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
| P0BF9-12 | Drive Motor "B" Phase W Current Sensor Circuit Short to Battery |
| P0BF9-14 | Drive Motor "B" Phase W Current Sensor Circuit Short to Ground or Open |
| P0BF9-28 | Drive Motor "B" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
| P0BFD-62 | Drive Motor A" Phase U-V-W Current Sensor Signal Compare Failure" |
| P0BFE-62 | Drive Motor "B" Phase U-V-W Current Sensor Signal Compare Failure |
| P0BFF-1D | Drive Motor "A" Circuit Current Out of Range |
| P0C02-1D | Drive Motor "B" System Circuit Current Out of Range |
| P0C19-00 | Drive Motor "A" Execution Torque Performance |
| P0C1A-00 | Drive Motor "B" Execution Torque Performance |
| P0C50-13 | Drive Motor "A" Position Sensor Circuit "A" Circuit Open |
| P0C50-16 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold |
| P0C50-17 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold |
| P0C50-1F | Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent |
| P0C55-13 | Drive Motor "B" Position Sensor Circuit "A" Circuit Open |
| P0C55-16 | Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Below Threshold |
| P0C55-17 | Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Above Threshold |
| P0C55-1F | Drive Motor "B" Position Sensor Circuit "A" Circuit Intermittent |
| P0C5A-13 | Drive Motor "A" Position Sensor Circuit "B" Circuit Open |
| P0C5A-16 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold |
| P0C5A-17 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold |
| P0C5A-1F | Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent |
| P0C5F-13 | Drive Motor "B" Position Sensor Circuit "B" Circuit Open |
| P0C5F-16 | Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Below Threshold |
| P0C5F-17 | Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Above Threshold |
| P0C5F-1F | Drive Motor "B" Position Sensor Circuit "B" Circuit Intermittent |
| P0C79-17 | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold |
| P0C7A-17 | Drive Motor "B" Inverter Voltage Sensor "A" Circuit Voltage Above Threshold |
| P0D2D-16 | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Below Threshold |
| P0D2D-17 | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold |
| P0D2D-1F | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Intermittent |
| P0DA3-16 | Drive Motor "B" Inverter Voltage Sensor "A" Circuit Voltage Below Threshold |
| P0DA3-17 | Drive Motor "B" Inverter Voltage Sensor "A" Circuit Voltage Above Threshold |
| P0DA3-1F | Drive Motor "B" Inverter Voltage Sensor "A" Circuit Intermittent |
| P163E-94 | Drive Motor "A" Control Module Monitoring System Unexpected Operation |
| P163F-94 | Drive Motor "B" Control Module Monitoring System Performance Unexpected Operation |
| P19F9-1C | Drive Motor "B" Control Module Offset Power Circuit Voltage Out of Range |
| P1BFA-46 | Internal Control Module (EEPROM Resolver Learning Value) Calibration / Parameter Memory Failure |
| P1C2B-1C | Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range |
| P1C2C-1C | Drive Motor "B" Control Module AD Converter Circuit Voltage Out of Range |
| P1C5D-19 | Drive Motor "A" Inverter Circuit Current Above Threshold |
| P1C5E-19 | Drive Motor "B" Inverter Circuit Current Above Threshold |
| P1C60-1F | Generator Control Module Position Sensor REF Power Source Circuit Intermittent |
| P1C62-1F | Generator Control Module Offset Power Circuit Intermittent |
| P1C63-1F | Drive Motor "B" Control Module Offset Power Circuit Intermittent |
| P1C65-1F | Generator Control Module Circuit Intermittent |
| P1C66-1F | Drive Motor "B" Control Module Circuit Intermittent |
| P1C67-1F | Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent |
| P1C68-1F | Drive Motor "B" Phase U-V-W Current Sensor Circuit Intermittent |
| P1C6A-9F | Motor Shutdown Stuck Off |
| P1C6B-9F | Rear Motor Shutdown Stuck Off |
| P1CAD-49 | Drive Motor "A" Position Sensor Internal Electronic Failure |
| P1CAE-49 | Drive Motor "B" Position Sensor Internal Electronic Failure |
| P1CB0-38 | Drive Motor "A" Position Sensor REF Signal Frequency Incorrect |
| P1CB1-38 | Drive Motor "B" Position Sensor REF Signal Frequency Incorrect |
| P1CB6-9E | Drive Motor "A" Inverter Voltage Sensor(VH) Stuck On |
| P1CE2-11 | PCU Interlock Circuit Short to Ground |
| P1CE4-9E | Drive Motor "B" Inverter Voltage Sensor "A" Stuck On |
| P1F67-11 | Rear PCU Interlock Circuit Short to Ground |
| P2600-31 | Motor/Generator Coolant Pump "A" Control Circuit No Signal |
| P2600-96 | Coolant Pump "A" Control Circuit Component Internal Failure |
| P26F4-31 | Coolant Pump "C" Control Circuit No Signal |
| P26F4-96 | Coolant Pump "C" Control Circuit Component Internal Failure |
| P274A-11 | Transmission Fluid Temperature Sensor "C" Circuit Short to Ground |
| P274A-15 | Transmission Fluid Temperature Sensor "C" Circuit Short to Auxiliary Battery or Open |
| P274A-1C | Transmission Fluid Temperature Sensor "C" Voltage Out of Range |
| P274A-1F | Transmission Fluid Temperature Sensor "C" Circuit Intermittent |
| P275A-11 | Transmission Fluid Temperature Sensor "D" Circuit Short to Ground |
| P275A-15 | Transmission Fluid Temperature Sensor "D" Circuit Short to Battery or Open |
| P275A-1C | Transmission Fluid Temperature Sensor "D" Circuit Voltage Out of Range |
| P275A-1F | Transmission Fluid Temperature Sensor "D" Circuit Intermittent |
| U0293-00 | Lost Communication with Hybrid/EV Powertrain Control Module |
| U0293-87 | Lost Communication with Hybrid/EV Powertrain Control Module Missing Message |
| U1150-87 | Lost Communication with Hybrid Powertrain Control Module (Hybrid/EV Battery Local Bus) Missing Message |
| U115E-87 | Lost Communication with Drive Motor Control Module "B" (ch3) Missing Message |
| U1170-00 | Lost Communication with Brake System Control Module (Gear Shift Control Module "A") |
| U1170-08 | Lost Communication with Brake System Control Module (ch2) Bus Signal / Message Failure |
| U11B3-08 | Lost Communication with Hybrid/EV Powertrain Control Module (ch5) Bus Signal / Message Failure |
| U11B3-87 | Lost Communication with Hybrid/EV Powertrain Control Module (ch5) Missing Message |
MOTOR GENERATOR CONTROL SYSTEM DIAGNOSTIC TROUBLE CODE (DTC) IDENTIFICATION [11/2023 - ]
| DTC Code | Description |
|---|---|
| P062F-46 | Generator Control Module(EEPROM Learning Value) Calibration / Parameter Memory Failure |
| P06B0-1C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
| P06B3-1C | Drive Motor "B" Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
| P06B3-1F | Drive Motor "B" Control Module Position Sensor REF Power Source Circuit Intermittent |
| P06D6-1C | Generator Control Module Offset Power Circuit Voltage Out of Range |
| P0A00-11 | Motor Electronics Coolant Temperature Sensor Circuit Short to Ground |
| P0A00-15 | Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open |
| P0A00-1C | Motor Electronics Coolant Temperature Sensor Circuit Voltage Out of Range |
| P0A1B-00 | Drive Motor "A" Control Module Performance |
| P0A1B-04 | Drive Motor "A" Control Module System Internal Failure |
| P0A1B-1F | Generator Control Module Circuit Intermittent |
| P0A1B-29 | Drive Motor "A" Control Module Signal Invalid |
| P0A1B-47 | Drive Motor "A" Control Module Watchdog / Safety MC Failure |
| P0A1C-00 | Drive Motor "B" Control Module Performance |
| P0A1C-04 | Drive Motor "B" Control Module System Internal Failure |
| P0A1C-1F | Drive Motor "B" Control Module Circuit Intermittent |
| P0A1C-29 | Drive Motor "B" Control Module Signal Invalid |
| P0A1C-47 | Drive Motor "B" Control Module Watchdog / Safety MCU Failure |
| P0A2A-11 | Drive Motor "A" Temperature Sensor Circuit Short to Ground |
| P0A2A-15 | Drive Motor "A" Temperature Sensor Circuit Short to Auxiliary Battery or Open |
| P0A2A-1C | Drive Motor "A" Temperature Sensor Voltage Out of Range |
| P0A2A-1F | Drive Motor "A" Temperature Sensor Circuit Intermittent |
| P0A30-11 | Drive Motor "B" Temperature Sensor Circuit Short to Ground |
| P0A30-15 | Drive Motor "B" Temperature Sensor Circuit Short to Battery or Open |
| P0A30-1C | Drive Motor "B" Temperature Sensor Circuit Voltage Out of Range |
| P0A30-1F | Drive Motor "B" Temperature Sensor Circuit Intermittent |
| P0A3F-16 | Drive Motor "A" Position Sensor Circuit Voltage Below Threshold |
| P0A3F-1F | Drive Motor "A" Position Sensor Circuit Intermittent |
| P0A3F-21 | Drive Motor "A" Position Sensor Signal Amplitude < Minimum |
| P0A3F-22 | Drive Motor "A" Position Sensor Signal Amplitude > Maximum |
| P0A3F-2B | Drive Motor "A" Position Sensor Signal Cross Coupled |
| P0A45-16 | Drive Motor "B" Position Sensor Circuit Voltage Below Threshold |
| P0A45-1F | Drive Motor "B" Position Sensor Circuit Intermittent |
| P0A45-21 | Drive Motor "B" Position Sensor Signal Amplitude < Minimum |
| P0A45-22 | Drive Motor "B" Position Sensor Signal Amplitude > Maximum |
| P0A45-2B | Drive Motor "B" Position Sensor Signal Cross Coupled |
| P0A5D-12 | Drive Motor "A" Phase U Current (High Resolution) Circuit Short to Battery |
| P0A5D-14 | Drive Motor "A" Phase U Current (High Resolution) Circuit Short to Ground or Open |
| P0A5D-1C | Drive Motor "A" Phase U Current (High Resolution) Circuit Voltage Out of Range |
| P0A5D-1F | Drive Motor "A" Phase U Current (High Resolution) Circuit Intermittent |
| P0A63-12 | Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Battery |
| P0A63-14 | Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Ground or Open |
| P0A63-1C | Drive Motor "A" Phase W Current(High Resolution) Circuit Voltage Out of Range |
| P0A63-1F | Drive Motor "A" Phase W Current(High Resolution) Circuit Intermittent |
| P0A66-12 | Drive Motor "B" Phase U Current (High Resolution) Circuit Short to Battery |
| P0A66-14 | Drive Motor "B" Phase U Current (High Resolution) Circuit Short to Ground or Open |
| P0A66-1C | Drive Motor "B" Phase U Current (High Resolution) Circuit Voltage Out of Range |
| P0A66-1F | Drive Motor "B" Phase U Current (High Resolution) Circuit Intermittent |
| P0A6C-12 | Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Battery |
| P0A6C-14 | Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Ground or Open |
| P0A6C-1C | Drive Motor "B" Phase W Current(High Resolution) Circuit Voltage Out of Range |
| P0A6C-1F | Drive Motor "B" Phase W Current(High Resolution) Circuit Intermittent |
| P0A78-72 | Drive Motor "A" Inverter Actuator Stuck Open |
| P0A78-73 | Drive Motor "A" Inverter Actuator Stuck Closed |
| P0A78-9E | Drive Motor "A" Inverter Stuck On |
| P0A79-72 | Drive Motor "B" Inverter Actuator Stuck Open |
| P0A79-73 | Drive Motor "B" Inverter Actuator Stuck Closed |
| P0A79-9E | Drive Motor "B" Inverter Stuck On |
| P0A90-00 | Drive Motor "A" Performance |
| P0A91-00 | Drive Motor "B" Performance |
| P0AED-11 | Drive Motor Inverter Temperature Sensor "A" Circuit Short to Ground |
| P0AED-15 | Drive Motor Inverter Temperature Sensor "A" Circuit Short to Battery or Open |
| P0AED-1C | Drive Motor Inverter Temperature Sensor "A" Circuit Voltage Out of Range |
| P0AF2-11 | Drive Motor Inverter Temperature Sensor "B" Circuit Short to Ground |
| P0AF2-15 | Drive Motor Inverter Temperature Sensor "B" Circuit Short to Battery or Open |
| P0AF2-1C | Drive Motor Inverter Temperature Sensor "B" Circuit Voltage Out of Range |
| P0BE5-12 | Drive Motor "A" Phase U Current Sensor Circuit Short to Battery |
| P0BE5-14 | Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open |
| P0BE5-28 | Drive Motor A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure" |
| P0BE9-12 | Drive Motor "A" Phase V Current Sensor Circuit Short to Battery |
| P0BE9-14 | Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open |
| P0BE9-28 | Drive Motor A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure" |
| P0BED-12 | Drive Motor "A" Phase W Current Sensor Circuit Short to Battery |
| P0BED-14 | Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open |
| P0BED-28 | Drive Motor A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure" |
| P0BF1-12 | Drive Motor "B" Phase U Current Sensor Circuit Short to Battery |
| P0BF1-14 | Drive Motor "B" Phase U Current Sensor Circuit Short to Ground or Open |
| P0BF1-28 | Drive Motor "B" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
| P0BF5-12 | Drive Motor "B" Phase V Current Sensor Circuit Short to Battery |
| P0BF5-14 | Drive Motor "B" Phase V Current Sensor Circuit Short to Ground or Open |
| P0BF5-28 | Drive Motor "B" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
| P0BF9-12 | Drive Motor "B" Phase W Current Sensor Circuit Short to Battery |
| P0BF9-14 | Drive Motor "B" Phase W Current Sensor Circuit Short to Ground or Open |
| P0BF9-28 | Drive Motor "B" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
| P0BFD-62 | Drive Motor A" Phase U-V-W Current Sensor Signal Compare Failure" |
| P0BFE-62 | Drive Motor "B" Phase U-V-W Current Sensor Signal Compare Failure |
| P0BFF-1D | Drive Motor "A" Circuit Current Out of Range |
| P0C02-1D | Drive Motor "B" System Circuit Current Out of Range |
| P0C19-00 | Drive Motor "A" Execution Torque Performance |
| P0C1A-00 | Drive Motor "B" Execution Torque Performance |
| P0C50-13 | Drive Motor "A" Position Sensor Circuit "A" Circuit Open |
| P0C50-16 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold |
| P0C50-17 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold |
| P0C50-1F | Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent |
| P0C55-13 | Drive Motor "B" Position Sensor Circuit "A" Circuit Open |
| P0C55-16 | Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Below Threshold |
| P0C55-17 | Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Above Threshold |
| P0C55-1F | Drive Motor "B" Position Sensor Circuit "A" Circuit Intermittent |
| P0C5A-13 | Drive Motor "A" Position Sensor Circuit "B" Circuit Open |
| P0C5A-16 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold |
| P0C5A-17 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold |
| P0C5A-1F | Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent |
| P0C5F-13 | Drive Motor "B" Position Sensor Circuit "B" Circuit Open |
| P0C5F-16 | Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Below Threshold |
| P0C5F-17 | Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Above Threshold |
| P0C5F-1F | Drive Motor "B" Position Sensor Circuit "B" Circuit Intermittent |
| P0C79-17 | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold |
| P0C7A-17 | Drive Motor "B" Inverter Voltage Sensor "A" Circuit Voltage Above Threshold |
| P0D2D-16 | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Below Threshold |
| P0D2D-17 | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold |
| P0D2D-1F | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Intermittent |
| P0DA3-16 | Drive Motor "B" Inverter Voltage Sensor "A" Circuit Voltage Below Threshold |
| P0DA3-17 | Drive Motor "B" Inverter Voltage Sensor "A" Circuit Voltage Above Threshold |
| P0DA3-1F | Drive Motor "B" Inverter Voltage Sensor "A" Circuit Intermittent |
| P163E-94 | Drive Motor "A" Control Module Monitoring System Unexpected Operation |
| P163F-94 | Drive Motor "B" Control Module Monitoring System Performance Unexpected Operation |
| P19F9-1C | Drive Motor "B" Control Module Offset Power Circuit Voltage Out of Range |
| P1BFA-46 | Internal Control Module (EEPROM Resolver Learning Value) Calibration / Parameter Memory Failure |
| P1C2B-1C | Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range |
| P1C2C-1C | Drive Motor "B" Control Module AD Converter Circuit Voltage Out of Range |
| P1C5D-19 | Drive Motor "A" Inverter Circuit Current Above Threshold |
| P1C5E-19 | Drive Motor "B" Inverter Circuit Current Above Threshold |
| P1C60-1F | Generator Control Module Position Sensor REF Power Source Circuit Intermittent |
| P1C62-1F | Generator Control Module Offset Power Circuit Intermittent |
| P1C63-1F | Drive Motor "B" Control Module Offset Power Circuit Intermittent |
| P1C65-1F | Generator Control Module Circuit Intermittent |
| P1C66-1F | Drive Motor "B" Control Module Circuit Intermittent |
| P1C67-1F | Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent |
| P1C68-1F | Drive Motor "B" Phase U-V-W Current Sensor Circuit Intermittent |
| P1C6A-9F | Motor Shutdown Stuck Off |
| P1C6B-9F | Rear Motor Shutdown Stuck Off |
| P1CAD-49 | Drive Motor "A" Position Sensor Internal Electronic Failure |
| P1CAE-49 | Drive Motor "B" Position Sensor Internal Electronic Failure |
| P1CB0-38 | Drive Motor "A" Position Sensor REF Signal Frequency Incorrect |
| P1CB1-38 | Drive Motor "B" Position Sensor REF Signal Frequency Incorrect |
| P1CB6-9E | Drive Motor "A" Inverter Voltage Sensor(VH) Stuck On |
| P1CE2-11 | PCU Interlock Circuit Short to Ground |
| P1CE4-9E | Drive Motor "B" Inverter Voltage Sensor "A" Stuck On |
| P1F67-11 | Rear PCU Interlock Circuit Short to Ground |
| P2600-31 | Motor/Generator Coolant Pump "A" Control Circuit No Signal |
| P2600-96 | Coolant Pump "A" Control Circuit Component Internal Failure |
| P26F4-31 | Coolant Pump "C" Control Circuit No Signal |
| P26F4-96 | Coolant Pump "C" Control Circuit Component Internal Failure |
| P274A-11 | Transmission Fluid Temperature Sensor "C" Circuit Short to Ground |
| P274A-15 | Transmission Fluid Temperature Sensor "C" Circuit Short to Auxiliary Battery or Open |
| P274A-1C | Transmission Fluid Temperature Sensor "C" Voltage Out of Range |
| P274A-1F | Transmission Fluid Temperature Sensor "C" Circuit Intermittent |
| P275A-11 | Transmission Fluid Temperature Sensor "D" Circuit Short to Ground |
| P275A-15 | Transmission Fluid Temperature Sensor "D" Circuit Short to Battery or Open |
| P275A-1C | Transmission Fluid Temperature Sensor "D" Circuit Voltage Out of Range |
| P275A-1F | Transmission Fluid Temperature Sensor "D" Circuit Intermittent |
| U0293-00 | Lost Communication with Hybrid/EV Powertrain Control Module |
| U0293-87 | Lost Communication with Hybrid/EV Powertrain Control Module Missing Message |
| U1150-87 | Lost Communication with Hybrid Powertrain Control Module (Hybrid/EV Battery Local Bus) Missing Message |
| U115E-87 | Lost Communication with Drive Motor Control Module "B" (ch3) Missing Message |
| U1170-00 | Lost Communication with Brake System Control Module (Gear Shift Control Module "A") |
| U1170-08 | Lost Communication with Brake System Control Module (ch2) Bus Signal / Message Failure |
| U11B3-08 | Lost Communication with Hybrid/EV Powertrain Control Module (ch5) Bus Signal / Message Failure |
| U11B3-87 | Lost Communication with Hybrid/EV Powertrain Control Module (ch5) Missing Message |
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.