2022 Lexus UX 200 BaseFACTORY OEM SERVICE PROCEDURE

Motor Generator Control System

MOTOR GENERATOR CONTROL SYSTEM DIAGNOSTIC TROUBLE CODE (DTC) IDENTIFICATION

DTC Code Description
P0335-00 Crankshaft Position Sensor "A"
P0335-31 Crankshaft Position Sensor "A" No Signal
P0340-00 Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor
P0340-31 Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor No Signal
P062F-44 Internal Control Module EEPROM Data Memory Failure
P062F-46 Generator Control Module (EEPROM Learning Value) Calibration / Parameter Memory Failure
P06B0-1C Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range
P06D6-1C Generator Control Module Offset Power Circuit Voltage Out of Range
P0A00-11 Motor Electronics Coolant Temperature Sensor Circuit Short to Ground
P0A00-15 Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open
P0A00-1C Motor Electronics Coolant Temperature Sensor Circuit Voltage Out of Range
P0A08-12 DC/DC Converter Status Circuit Short to Battery
P0A08-14 DC/DC Converter Status Circuit Short to Ground or Open
P0A11-12 DC/DC Converter Enable Circuit Short to Battery
P0A11-14 DC/DC Converter Enable Circuit Short to Ground or Open
P0A1A-47 Generator Control Module Watchdog / Safety μC Failure
P0A1A-49 Generator Control Module Internal Electronic Failure
P0A1B-1F Generator Control Module Circuit Intermittent
P0A1C-49 Drive Motor "B" Control Module Internal Electronic Failure
P0A3F-16 Drive Motor "A" Position Sensor Circuit Voltage Below Threshold
P0A3F-1F Drive Motor "A" Position Sensor Circuit Intermittent
P0A3F-21 Drive Motor "A" Position Sensor Signal Amplitude < Minimum
P0A3F-22 Drive Motor "A" Position Sensor Signal Amplitude > Maximum
P0A4B-16 Generator Position Sensor Circuit Voltage Below Threshold
P0A4B-1F Generator Position Sensor Circuit Intermittent
P0A4B-21 Generator Position Sensor Signal Amplitude < Minimum
P0A4B-22 Generator Position Sensor Signal Amplitude > Maximum
P0A60-12 Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery
P0A60-14 Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open
P0A60-1C Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range
P0A60-1F Drive Motor "A" Phase V Current (High Resolution) Circuit Intermittent
P0A63-12 Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery
P0A63-14 Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open
P0A63-1C Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range
P0A63-1F Drive Motor "A" Phase W Current (High Resolution) Circuit Intermittent
P0A78-72 Drive Motor "A" Inverter Actuator Stuck Open
P0A78-73 Drive Motor "A" Inverter Actuator Stuck Closed
P0A78-9E Drive Motor "A" Inverter Stuck On
P0A7A-72 Generator Inverter Actuator Stuck Open
P0A7A-73 Generator Inverter Actuator Stuck Closed
P0A7A-9E Generator Inverter Stuck On
P0A90-00 Drive Motor "A" Performance
P0A92-00 Hybrid Generator Performance
P0A94-9E DC/DC Converter Stuck On
P0AED-11 Drive Motor Inverter Temperature Sensor "A" Circuit Short to Ground
P0AED-15 Drive Motor Inverter Temperature Sensor "A" Circuit Short to Battery or Open
P0AED-1C Drive Motor Inverter Temperature Sensor "A" Circuit Voltage Out of Range
P0BE5-12 Drive Motor "A" Phase U Current Sensor Circuit Short to Battery
P0BE5-14 Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open
P0BE5-1F Drive Motor "A" Phase U Current Sensor Circuit Intermittent
P0BE5-28 Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0BE9-12 Drive Motor "A" Phase V Current Sensor Circuit Short to Battery
P0BE9-14 Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open
P0BE9-1F Drive Motor "A" Phase V Current Sensor Circuit Intermittent
P0BE9-28 Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0BED-12 Drive Motor "A" Phase W Current Sensor Circuit Short to Battery
P0BED-14 Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open
P0BED-1F Drive Motor "A" Phase W Current Sensor Circuit Intermittent
P0BED-28 Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0BFD-62 Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure
P0BFF-1D Drive Motor "A" Circuit Current Out of Range
P0C19-00 Drive Motor "A" Execution Torque Performance
P0C38-11 DC/DC Converter Temperature Sensor "A" Circuit Short to Ground
P0C38-15 DC/DC Converter Temperature Sensor "A" Circuit Short to Battery or Open
P0C38-1C DC/DC Converter Temperature Sensor "A" Circuit Voltage Out of Range
P0C3D-11 DC/DC Converter Temperature Sensor "B" Circuit Short to Ground
P0C3D-15 DC/DC Converter Temperature Sensor "B" Circuit Short to Battery or Open
P0C3D-1C DC/DC Converter Temperature Sensor "B" Circuit Voltage Out of Range
P0C50-13 Drive Motor "A" Position Sensor Circuit "A" Circuit Open
P0C50-16 Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold
P0C50-17 Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold
P0C50-1F Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent
P0C5A-13 Drive Motor "A" Position Sensor Circuit "B" Circuit Open
P0C5A-16 Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold
P0C5A-17 Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold
P0C5A-1F Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent
P0C64-13 Generator Position Sensor Circuit "A" Circuit Open
P0C64-16 Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold
P0C64-17 Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold
P0C64-1F Generator Position Sensor Circuit "A" Circuit Intermittent
P0C69-13 Generator Position Sensor Circuit "B" Circuit Open
P0C69-16 Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold
P0C69-17 Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold
P0C69-1F Generator Position Sensor Circuit "B" Circuit Intermittent
P0C79-17 Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold
P0CA3-00 DC/DC Converter Step Up Voltage Performance
P0D2D-16 Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold
P0D2D-17 Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold
P0D2D-1F Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Intermittent
P0D33-19 DC/DC Converter Circuit Current Above Threshold
P0DFA-62 Generator Phase U-V-W Current Sensor Signal Compare Failure
P0E00-12 Generator Phase U Current Sensor Circuit Short to Battery
P0E00-14 Generator Phase U Current Sensor Circuit Short to Ground or Open
P0E00-1F Generator Phase U Current Sensor Circuit Intermittent
P0E00-28 Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0E04-12 Generator Phase V Current Sensor Circuit Short to Battery
P0E04-14 Generator Phase V Current Sensor Circuit Short to Ground or Open
P0E04-1F Generator Phase V Current Sensor Circuit Intermittent
P0E04-28 Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0E08-12 Generator Phase W Current Sensor Circuit Short to Battery
P0E08-14 Generator Phase W Current Sensor Circuit Short to Ground or Open
P0E08-1F Generator Phase W Current Sensor Circuit Intermittent
P0E08-28 Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0E31-16 DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Below Threshold
P0E31-17 DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold
P0E31-1F DC/DC Converter Voltage Sensor "A" (VL) Circuit Intermittent
P0E51-11 DC/DC Converter Current Sensor Circuit Short to Ground
P0E51-15 DC/DC Converter Current Sensor Circuit Short to Battery or Open
P0E51-1F DC/DC Converter Current Sensor Circuit Intermittent
P0E51-28 DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0E51-2A DC/DC Converter Current Sensor Signal Stuck In Range
P0E57-17 DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold
P0E58-11 DC/DC Converter Temperature Sensor 2 Circuit Short to Ground
P0E58-15 DC/DC Converter Temperature Sensor 2 Circuit Short to Battery or Open
P0E58-1C DC/DC Converter Temperature Sensor 2 Circuit Voltage Out of Range
P0E71-00 Generator Execution Torque Performance
P1C2A-1C Generator A/D Converter Circuit Circuit Voltage Out of Range
P1C2A-49 Generator A/D Converter Circuit Internal Electronic Failure
P1C2B-1C Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range
P1C2B-49 Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure
P1C2E-46 Motor Generator ECU (EEPROM) Calibration / Parameter Memory Failure
P1C5D-19 Drive Motor "A" Inverter Circuit Current Above Threshold
P1C5F-19 Generator Inverter Circuit Current Above Threshold
P1C60-1F Generator Control Module Position Sensor REF Power Source Circuit Intermittent
P1C62-1F Generator Control Module Offset Power Circuit Intermittent
P1C64-1F Generator Control Module Circuit Intermittent
P1C65-1F Generator Control Module Circuit Intermittent
P1C67-1F Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent
P1C69-1F Generator Phase U-V-W Current Sensor Circuit Intermittent
P1CA5-1D Hybrid Generator Circuit Current Out of Range
P1CAC-49 Generator Position Sensor Internal Electronic Failure
P1CAD-49 Drive Motor "A" Position Sensor Internal Electronic Failure
P1CAF-38 Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect
P1CB0-38 Drive Motor "A" Position Sensor REF Signal Frequency Incorrect
P1CB5-9E DC/DC Converter Voltage Sensor "A" (VL) Stuck On
P1CB6-9E Drive Motor "A" Inverter Voltage Sensor (VH) Stuck On
P1CCC-96 DC/DC Converter Enable Component Internal Failure
P1CFF-62 Hybrid/EV Battery Current/DC/DC Converter Current Signal Compare Failure
P3124-1F Lost Communication between Drive Motor "A" and HV ECU Circuit Intermittent
P3124-87 Lost Communication between Drive Motor "A" and HV ECU Missing Message
P3133-83 Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect
P3133-86 Communication Error from Generator to Drive Motor "A" Signal Invalid
P3133-87 Communication Error from Generator to Drive Motor "A" Missing Message
P3134-83 Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect
P3134-86 Communication Error from Drive Motor "A" to Generator Signal Invalid
P3134-87 Communication Error from Drive Motor "A" to Generator Missing Message
P3148-1F Lost Communication between Drive Motor "A" and "B" Circuit Intermittent
P3148-87 Lost Communication between Drive Motor "A" and "B" Missing Message
P314F-1F DC/DC Converter Voltage Sensor "A" (VL) Circuit Intermittent
P3153-1D DC/DC Converter Current Sensor Circuit Current Out of Range
U0100-87 Lost Communication With ECM/PCM "A" Missing Message
U0293-87 Lost Communication With Hybrid Powertrain Control Module Missing Message
U1170-87 Lost Communication With Brake System Control Module (ch2) Missing Message
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.

Rather have a pro handle this?

A certified mobile mechanic comes to your home or office. They bring the tools, you stay comfortable. No tow truck, no waiting room, no surprises.

Comes to youSame-day available12-month warranty
Get a Free Quote

No obligation. See pricing before you book.