2021 Lexus RC F BaseFACTORY OEM SERVICE PROCEDURE

Jam Protection Function does not Operate [09/2014 - ]: Procedure

  1. PERFORM INITIALIZATION (APPLICABLE LOCATION) 
    1. Initialize the power window regulator motor assembly (applicable location).

      Refer to INITIALIZATION [09/2014 - ]

      Result

      Proceed to
      NEXT

    Result: 

    NEXT 

    See step  2

  2. CHECK POWER WINDOW CONTROL SYSTEM (AUTO UP / DOWN FUNCTION) 
    1. Check if the power window auto up and down functions operate normally.

      Refer to OPERATION CHECK [09/2014 - ]

      OK

      Auto up and down functions are normal.

      Result

      Proceed to
      OK
      NG

    Result: 

    NG 

    GO TO OTHER PROBLEM (Proceed to Problem Symptoms Table). Refer to  PROBLEM SYMPTOMS TABLE [09/2014 - ] 

    Result: 

    OK 

    See step  3

  3. CHECK JAM PROTECTION FUNCTION OPERATING RANGE 
    1. Check if the jam protection function operates normally for the applicable power window.

      HINT: 

      The jam protection function will not operate within 4 mm (0.157 in.) of the fully closed position.

      OK

      Jam protection function operates normally.

      Result

      Result Proceed to
      OK A
      NG (Driver door power window) B
      NG (Front passenger door power window)

    Result: 

    A 

    END (PROBLEM DUE TO INITIALIZATION FAILURE) 

    Result: 

    B 

    REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY (FOR DRIVER DOOR OR FRONT PASSENGER DOOR). Refer to  REMOVAL [09/2014 - ] 

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.