2020 Lexus UX 200 BaseFACTORY OEM SERVICE PROCEDURE
Motor Generator Control System
MOTOR GENERATOR CONTROL SYSTEM DIAGNOSTIC TROUBLE CODE (DTC) IDENTIFICATION
| DTC Code | Description |
|---|---|
| P0335-00 | Crankshaft Position Sensor "A" |
| P0335-31 | Crankshaft Position Sensor "A" No Signal |
| P0340-00 | Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor |
| P0340-31 | Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor No Signal |
| P062F-44 | Internal Control Module EEPROM Data Memory Failure |
| P062F-46 | Generator Control Module (EEPROM Learning Value) Calibration / Parameter Memory Failure |
| P06B0-1C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
| P06D6-1C | Generator Control Module Offset Power Circuit Voltage Out of Range |
| P0A00-11 | Motor Electronics Coolant Temperature Sensor Circuit Short to Ground |
| P0A00-15 | Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open |
| P0A00-1C | Motor Electronics Coolant Temperature Sensor Circuit Voltage Out of Range |
| P0A08-12 | DC/DC Converter Status Circuit Short to Battery |
| P0A08-14 | DC/DC Converter Status Circuit Short to Ground or Open |
| P0A11-12 | DC/DC Converter Enable Circuit Short to Battery |
| P0A11-14 | DC/DC Converter Enable Circuit Short to Ground or Open |
| P0A1A-47 | Generator Control Module Watchdog / Safety μC Failure |
| P0A1A-49 | Generator Control Module Internal Electronic Failure |
| P0A1B-1F | Generator Control Module Circuit Intermittent |
| P0A1C-49 | Drive Motor "B" Control Module Internal Electronic Failure |
| P0A3F-16 | Drive Motor "A" Position Sensor Circuit Voltage Below Threshold |
| P0A3F-1F | Drive Motor "A" Position Sensor Circuit Intermittent |
| P0A3F-21 | Drive Motor "A" Position Sensor Signal Amplitude < Minimum |
| P0A3F-22 | Drive Motor "A" Position Sensor Signal Amplitude > Maximum |
| P0A4B-16 | Generator Position Sensor Circuit Voltage Below Threshold |
| P0A4B-1F | Generator Position Sensor Circuit Intermittent |
| P0A4B-21 | Generator Position Sensor Signal Amplitude < Minimum |
| P0A4B-22 | Generator Position Sensor Signal Amplitude > Maximum |
| P0A60-12 | Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery |
| P0A60-14 | Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open |
| P0A60-1C | Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range |
| P0A60-1F | Drive Motor "A" Phase V Current (High Resolution) Circuit Intermittent |
| P0A63-12 | Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery |
| P0A63-14 | Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open |
| P0A63-1C | Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range |
| P0A63-1F | Drive Motor "A" Phase W Current (High Resolution) Circuit Intermittent |
| P0A78-72 | Drive Motor "A" Inverter Actuator Stuck Open |
| P0A78-73 | Drive Motor "A" Inverter Actuator Stuck Closed |
| P0A78-9E | Drive Motor "A" Inverter Stuck On |
| P0A7A-72 | Generator Inverter Actuator Stuck Open |
| P0A7A-73 | Generator Inverter Actuator Stuck Closed |
| P0A7A-9E | Generator Inverter Stuck On |
| P0A90-00 | Drive Motor "A" Performance |
| P0A92-00 | Hybrid Generator Performance |
| P0A94-9E | DC/DC Converter Stuck On |
| P0AED-11 | Drive Motor Inverter Temperature Sensor "A" Circuit Short to Ground |
| P0AED-15 | Drive Motor Inverter Temperature Sensor "A" Circuit Short to Battery or Open |
| P0AED-1C | Drive Motor Inverter Temperature Sensor "A" Circuit Voltage Out of Range |
| P0BE5-12 | Drive Motor "A" Phase U Current Sensor Circuit Short to Battery |
| P0BE5-14 | Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open |
| P0BE5-1F | Drive Motor "A" Phase U Current Sensor Circuit Intermittent |
| P0BE5-28 | Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
| P0BE9-12 | Drive Motor "A" Phase V Current Sensor Circuit Short to Battery |
| P0BE9-14 | Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open |
| P0BE9-1F | Drive Motor "A" Phase V Current Sensor Circuit Intermittent |
| P0BE9-28 | Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
| P0BED-12 | Drive Motor "A" Phase W Current Sensor Circuit Short to Battery |
| P0BED-14 | Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open |
| P0BED-1F | Drive Motor "A" Phase W Current Sensor Circuit Intermittent |
| P0BED-28 | Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
| P0BFD-62 | Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure |
| P0BFF-1D | Drive Motor "A" Circuit Current Out of Range |
| P0C19-00 | Drive Motor "A" Execution Torque Performance |
| P0C38-11 | DC/DC Converter Temperature Sensor "A" Circuit Short to Ground |
| P0C38-15 | DC/DC Converter Temperature Sensor "A" Circuit Short to Battery or Open |
| P0C38-1C | DC/DC Converter Temperature Sensor "A" Circuit Voltage Out of Range |
| P0C3D-11 | DC/DC Converter Temperature Sensor "B" Circuit Short to Ground |
| P0C3D-15 | DC/DC Converter Temperature Sensor "B" Circuit Short to Battery or Open |
| P0C3D-1C | DC/DC Converter Temperature Sensor "B" Circuit Voltage Out of Range |
| P0C50-13 | Drive Motor "A" Position Sensor Circuit "A" Circuit Open |
| P0C50-16 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold |
| P0C50-17 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold |
| P0C50-1F | Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent |
| P0C5A-13 | Drive Motor "A" Position Sensor Circuit "B" Circuit Open |
| P0C5A-16 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold |
| P0C5A-17 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold |
| P0C5A-1F | Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent |
| P0C64-13 | Generator Position Sensor Circuit "A" Circuit Open |
| P0C64-16 | Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold |
| P0C64-17 | Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold |
| P0C64-1F | Generator Position Sensor Circuit "A" Circuit Intermittent |
| P0C69-13 | Generator Position Sensor Circuit "B" Circuit Open |
| P0C69-16 | Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold |
| P0C69-17 | Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold |
| P0C69-1F | Generator Position Sensor Circuit "B" Circuit Intermittent |
| P0C79-17 | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold |
| P0CA3-00 | DC/DC Converter Step Up Voltage Performance |
| P0D2D-16 | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold |
| P0D2D-17 | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold |
| P0D2D-1F | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Intermittent |
| P0D33-19 | DC/DC Converter Circuit Current Above Threshold |
| P0DFA-62 | Generator Phase U-V-W Current Sensor Signal Compare Failure |
| P0E00-12 | Generator Phase U Current Sensor Circuit Short to Battery |
| P0E00-14 | Generator Phase U Current Sensor Circuit Short to Ground or Open |
| P0E00-1F | Generator Phase U Current Sensor Circuit Intermittent |
| P0E00-28 | Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
| P0E04-12 | Generator Phase V Current Sensor Circuit Short to Battery |
| P0E04-14 | Generator Phase V Current Sensor Circuit Short to Ground or Open |
| P0E04-1F | Generator Phase V Current Sensor Circuit Intermittent |
| P0E04-28 | Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
| P0E08-12 | Generator Phase W Current Sensor Circuit Short to Battery |
| P0E08-14 | Generator Phase W Current Sensor Circuit Short to Ground or Open |
| P0E08-1F | Generator Phase W Current Sensor Circuit Intermittent |
| P0E08-28 | Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
| P0E31-16 | DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Below Threshold |
| P0E31-17 | DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold |
| P0E31-1F | DC/DC Converter Voltage Sensor "A" (VL) Circuit Intermittent |
| P0E51-11 | DC/DC Converter Current Sensor Circuit Short to Ground |
| P0E51-15 | DC/DC Converter Current Sensor Circuit Short to Battery or Open |
| P0E51-1F | DC/DC Converter Current Sensor Circuit Intermittent |
| P0E51-28 | DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
| P0E51-2A | DC/DC Converter Current Sensor Signal Stuck In Range |
| P0E57-17 | DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold |
| P0E58-11 | DC/DC Converter Temperature Sensor 2 Circuit Short to Ground |
| P0E58-15 | DC/DC Converter Temperature Sensor 2 Circuit Short to Battery or Open |
| P0E58-1C | DC/DC Converter Temperature Sensor 2 Circuit Voltage Out of Range |
| P0E71-00 | Generator Execution Torque Performance |
| P1C2A-1C | Generator A/D Converter Circuit Circuit Voltage Out of Range |
| P1C2A-49 | Generator A/D Converter Circuit Internal Electronic Failure |
| P1C2B-1C | Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range |
| P1C2B-49 | Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure |
| P1C2E-46 | Motor Generator ECU (EEPROM) Calibration / Parameter Memory Failure |
| P1C5D-19 | Drive Motor "A" Inverter Circuit Current Above Threshold |
| P1C5F-19 | Generator Inverter Circuit Current Above Threshold |
| P1C60-1F | Generator Control Module Position Sensor REF Power Source Circuit Intermittent |
| P1C62-1F | Generator Control Module Offset Power Circuit Intermittent |
| P1C64-1F | Generator Control Module Circuit Intermittent |
| P1C65-1F | Generator Control Module Circuit Intermittent |
| P1C67-1F | Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent |
| P1C69-1F | Generator Phase U-V-W Current Sensor Circuit Intermittent |
| P1CA5-1D | Hybrid Generator Circuit Current Out of Range |
| P1CAC-49 | Generator Position Sensor Internal Electronic Failure |
| P1CAD-49 | Drive Motor "A" Position Sensor Internal Electronic Failure |
| P1CAF-38 | Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect |
| P1CB0-38 | Drive Motor "A" Position Sensor REF Signal Frequency Incorrect |
| P1CB5-9E | DC/DC Converter Voltage Sensor "A" (VL) Stuck On |
| P1CB6-9E | Drive Motor "A" Inverter Voltage Sensor (VH) Stuck On |
| P1CCC-96 | DC/DC Converter Enable Component Internal Failure |
| P1CFF-62 | Hybrid/EV Battery Current/DC/DC Converter Current Signal Compare Failure |
| P3124-1F | Lost Communication between Drive Motor "A" and HV ECU Circuit Intermittent |
| P3124-87 | Lost Communication between Drive Motor "A" and HV ECU Missing Message |
| P3133-83 | Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect |
| P3133-86 | Communication Error from Generator to Drive Motor "A" Signal Invalid |
| P3133-87 | Communication Error from Generator to Drive Motor "A" Missing Message |
| P3134-83 | Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect |
| P3134-86 | Communication Error from Drive Motor "A" to Generator Signal Invalid |
| P3134-87 | Communication Error from Drive Motor "A" to Generator Missing Message |
| P3148-1F | Lost Communication between Drive Motor "A" and "B" Circuit Intermittent |
| P3148-87 | Lost Communication between Drive Motor "A" and "B" Missing Message |
| P314F-1F | DC/DC Converter Voltage Sensor "A" (VL) Circuit Intermittent |
| P3153-1D | DC/DC Converter Current Sensor Circuit Current Out of Range |
| U0100-87 | Lost Communication With ECM/PCM "A" Missing Message |
| U0293-87 | Lost Communication With Hybrid Powertrain Control Module Missing Message |
| U1170-87 | Lost Communication With Brake System Control Module (ch2) Missing Message |
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.
Rather have a pro handle this?
A certified mobile mechanic comes to your home or office. They bring the tools, you stay comfortable. No tow truck, no waiting room, no surprises.
Comes to youSame-day available12-month warranty
Get a Free QuoteNo obligation. See pricing before you book.