Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
2010 Lexus LX 570FACTORY OEM SERVICE PROCEDURE
Generator (Service Information): Generator: Disassembly: Disassembly
- REMOVE GENERATOR PULLEY
- SST: 09820-63011
- 09820-06010
- 09820-06021
HINT:
SST 1-A and B 09820-06010 SST 2 09820-06021 - Hold SST 1-A with a torque wrench, and tighten SST 1-B clockwise to the specified torque.
Torque: 39 N*m (398 kgf*cm, 29 ft.*lbf)
NOTE:Check that SST is secured on the rotor shaft.
- Mount SST 2 in a vise.
- Insert SST 1-A and B into SST 2, and attach the pulley nut to SST 2.
- To loosen the pulley nut, turn SST 1-A in the direction shown in the illustration.
- SST: 09820-63011
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.