Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
Inspection Procedure
- CHECK OPERATION OF CRANKINGÂ
- When starting the engine, check whether the starter motor starts.
ResultÂ
RESULT REFERENCEStarter Condition Proceed to Not operating A Operating B
B: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLEÂ (See PROBLEM SYMPTOMS TABLE )
A: Go to Next StepÂ
- When starting the engine, check whether the starter motor starts.
- CHECK SMART ACCESS SYSTEM WITH PUSH-BUTTON START (ENGINE DOES NOT START)Â
- Refer to Smart Access System With Push-button Start [Engine does not Start] (see ENGINE DOES NOT START ).
NG: REPAIR SMART ACCESS SYSTEM WITH PUSH-BUTTON START (ENGINE DOES NOT START)Â (See ENGINE DOES NOT START )
OK: Go to Next StepÂ
- READ VALUE USING TECHSTREAM (STARTER SIGNAL)Â
- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG) and turn the Techstream ON.
- Enter the following menus: Powertrain/Engine/Data List/All Data/Starter Signal.
- Check the result when the engine switch is turned on (IG) and the engine is started.
StandardÂ
ENGINE SWITCH POSITIONSTARTER SIG Engine Switch Position OFF on (IG) ON ENGINE START
OK: Go to step  9
NG: Go to Next StepÂ
- INSPECT ECM (STAR AND STSW VOLTAGE)Â
- Measure the voltage according to the value (s) in the table below while cranking the engine.
Standard voltageÂ
STANDARD VOLTAGE SPECIFICATIONTester Connection Condition Specified Condition A14-2 (STAR) - E3-1 (E1) Cranking 11 to 14 V A14-27 (STSW) - E3-1 (E1) Cranking 11 to 14 V ResultÂ
RESULT REFERENCETerminal STAR Terminal STSW Proceed to 11 to 14 V 11 to 14 V A 0V 11 to 14 V B 0V 0V C
B: REPLACE ECMÂ (See REMOVALÂ )
C: GO TO SMART ACCESS SYSTEM WITH PUSH-BUTTON STARTÂ (See ENGINE DOES NOT START )
A: Go to Next StepÂ
- Measure the voltage according to the value (s) in the table below while cranking the engine.
- INSPECT STARTER CUT RELAY (ST CUT)Â
- Remove the ST CUT relay from the engine room No. 2 relay block.
- Measure the resistance according to the value (s) in the table below.
Standard resistanceÂ
STANDARD RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition 3-5 When no battery voltage applied to terminals 1 and 2 10 kΩ or higher 3-5 When battery voltage applied to terminals 1 and 2 Below 1 Ω
NG: REPLACE STARTER CUT RELAY (ST CUT)Â (See STARTER CUT RELAY )
OK: Go to Next StepÂ
- INSPECT PARK/NEUTRAL POSITION SWITCH ASSEMBLYÂ
- Disconnect the park/neutral position (PNP) switch connector.
- Measure the resistance according to the value (s) in the table below.
Standard resistanceÂ
STANDARD RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition 4 (B) - 5 (L) Shift position P Below 1 Ω 4 (B) - 5 (L) Shift position N Below 1 Ω
NG: REPLACE PARK/NEUTRAL POSITION SWITCH ASSEMBLYÂ (See REMOVAL )
OK: Go to Next StepÂ
- CHECK HARNESS AND CONNECTOR (STARTER CUT RELAY (ST CUT) - PARK/NEUTRAL POSITION SWITCH, ECM)Â
- Remove the ST CUT relay from the engine room No. 2 relay block.
- Disconnect the E49 PNP switch connector.
- Disconnect the A14 ECM connector.
- Measure the resistance according to the value (s) in the table below.
Standard resistance (Check for open)Â
STANDARD RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition ST CUT relay (3) - E49-4 (B) Always Below 1 Ω ST CUT relay (5) - A14-2 (STAR) Always Below 1 Ω Standard resistance (Check for short)Â
STANDARD RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition ST CUT relay (3) or E49-4 (B) - Body ground Always 10 kΩ or higher ST CUT relay (5) or A14-2 (STAR) - Body ground Always 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS OR CONNECTORÂ
OK: Go to Next StepÂ
- CHECK HARNESS AND CONNECTOR (STARTER CUT RELAY (ST CUT) - IGNITION RELAY NO. 2 (IG2), BODY GROUND)Â
- Remove the IG2 relay from the engine room No. 2 relay block.
- Remove the ST CUT relay from the engine room No. 2 relay block.
- Measure the resistance according to the value (s) in the table below.
Standard resistance (Check for open)Â
STANDARD RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition ST CUT relay (2) - IG2 relay (3) Always Below 1 Ω ST CUT relay (1) - Body ground Always Below 1 Ω Standard resistance (Check for short)Â
STANDARD RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition ST CUT relay (2) - Body ground Always 10 kΩ or higher IG2 relay (3) - Body ground Always 10 kΩ or higher
NG: REPLACE ENGINE ROOM NO. 2 RELAY BLOCK, JUNCTION BLOCKÂ
OK: REPLACE HARNESS OR CONNECTOR (IGNITION RELAY NO. 2 (IG2) - BATTERY)Â
- INSPECT STARTER RELAY (ST)Â
- Remove the ST relay from the engine room No. 2 relay block.
- Measure the resistance according to the value (s) in the table below.
Standard resistanceÂ
STANDARD RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition 3-5 When no battery voltage applied to terminals 1 and 2 10 kΩ or higher 3-5 When battery voltage applied to terminals 1 and 2 Below 1 Ω
NG: REPLACE STARTER RELAY (ST)Â (See STARTER RELAY )
OK: Go to Next StepÂ
- CHECK HARNESS AND CONNECTOR (STARTER RELAY (ST) - PARK/NEUTRAL POSITION SWITCH, BODY GROUND)Â
- Remove the ST relay from the engine room No. 2 relay block.
- Disconnect the E49 PNP switch connector.
- Measure the resistance according to the value (s) in the table below.
Standard resistance (Check for open)Â
STANDARD RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition ST relay (1) - E49-S (L) Always Below 1 Ω ST relay (2) - Body ground Always Below 1 Ω Standard resistance (Check for short)Â
STANDARD RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition ST relay (1) or E49-5 (L) - Body ground Always 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS OR CONNECTORÂ
OK: Go to Next StepÂ
- INSPECT STARTER ASSEMBLYÂ
- Inspect the starter assembly (see INSPECTION ).
NG: REPLACE STARTER ASSEMBLYÂ (See REMOVAL )
OK: Go to Next StepÂ
- CHECK HARNESS AND CONNECTOR (STARTER ASSEMBLY - STARTER RELAY (ST), BATTERY)Â
- Remove the ST relay from the engine room No. 2 relay block.
- Disconnect the E25 and F1 starter connectors.
- Disconnect the cable from the positive battery terminal.
- Measure the resistance according to the value (s) in the table below.
Standard resistance (Check for open)Â
STANDARD RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition ST relay (3) - E25-1 Always Below 1 Ω F1-1 - Battery cable (+) Always Below 1 Ω Standard resistance (Check for short)Â
STANDARD RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition ST relay (3) or E25-1 - Body ground Always 10 kΩ or higher F1-1 or Battery cable (+) - Body ground Always 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS OR CONNECTORÂ
OK: REPAIR OR REPLACE HARNESS OR CONNECTOR (STARTER RELAY (ST) - BATTERY)Â
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.