2009 Lexus IS FFACTORY OEM SERVICE PROCEDURE

Air Intake Control Circuit: Procedure

  1. CHECK VACUUM SWITCHING VALVE (VSV FOR AIR INTAKE CONTROL VALVE) 
    1. Inspect the VSV for air intake control valve. Refer to ON-VEHICLE INSPECTION - Step 3 .

    NG → REPLACE VSV (FOR AIR INTAKE CONTROL VALVE) 

    OK: Go to next step 

  2. INSPECT TERMINAL VOLTAGE (VSV FOR AIR INTAKE CONTROL VALVE CONNECTOR) 
    1. Disconnect the VSV for air intake control valve connector.
      Fig 1: Identifying Air Intake Control Valve VSV Connector A60
      GTY148278Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Turn the engine switch on (IG).
    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage

      Tester Connection Switch Condition Specified Condition
      2 - Body ground Engine switch on (IG) 11 to 14 V
    4. Reconnect the VSV connector.

    NG → REPAIR OR REPLACE HARNESS OR CONNECTOR (EFI NO. 2 FUSE - VSV FOR AIR INTAKE CONTROL VALVE) 

    OK: Go to next step 

  3. CHECK HARNESS AND CONNECTOR (VSV FOR AIR INTAKE CONTROL VALVE - ECM) 
    1. Disconnect the VSV for air intake control valve connector.
      Fig 2: Identifying VSV Connector A60 And ECM Connector E3
      GTY126112Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Disconnect the ECM connector.
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)

      Tester Connection Condition Specified Condition
      A60-1 (VSV for AICV) - E3-8 (AICV) Always Below 1 Ω

      Standard Resistance (Check for Short)

      Tester Connection Condition Specified Condition
      A60-1 (VSV for AICV) or E3-8 (AICV) - Body ground Always 10 kΩ or higher
    4. Reconnect the ECM connector.
    5. Reconnect the VSV connector.

    NG → REPAIR OR REPLACE HARNESS OR CONNECTOR (VSV FOR AIR INTAKE CONTROL VALVE - ECM) 

    OK: Go to next step 

  4. REPLACE ECM. Refer to  REMOVAL 
  5. INSPECT AIR INTAKE CONTROL VALVE 
    1. Inspect the intake air control valve.

    NG → REPLACE AIR CLEANER CASE 

    OK → See step   4 

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.